2.
Mounting Instructions
IMPORTANT
The employees responsible for the equipment, installation and verification must take into
consideration all the actions concerning this subject specified in IEC 60079-14:2013 ed. 5.0
(Electrical installations design, selection and erection) standard. In addition to general
specifications associated with any system installed in hazardous locations, special attention
should be paid for specific requirements regarding intrinsic safety.
2.1.
Base Unit
The base of the device comes with a magnet to the rear for easy mounting to a metal surface
inside or outside of the pump controller cabinet. The base mounts outside the hazardous area
and is not intended to meet hazardous location safety standards. The antenna must be fitted
with the band-pass filter, as this forms part of the FCC/IC radio approvals.