Electronics Specification
Remote and Base Transceiver Units Matched
Mac ID
(32bit) Specific; No External
Connection - Paired Unit
Data Rate
Readings/Sec
100
Radio Frequency Band
GHz
2.45
Radio Channels
Selectable (*)
14
Telemetry Range
Feet (Meters) (*)
100 - 1000 (30-300)
RF Power Output (Remote Unit)
dBm (*)
13-15.5
RF Power Output (Base Unit)
dBm (*)
12.5-14
Remote Unit Battery Life
Min @ 100 rps
(**)
12 to 18 months
Remote Unit Battery Type
Lithium D-Cell, 3.6V
DC
, 19Ah
(TL-5930/F).
Compensated Temperature Range
°F (°C)
-14° to 150° (-25° to 65°)
Operating Temperature Range
°F (°C)
-70° to 175° (-55° to 80°)
Base Unit
Power Supply
VDC, mA
12 - 24; Min. 250mA
Virtual Excitation (External Ref)
Voltage
VDC
4.8-10.1 (Ref 5 ± 0.05)
Virtual Bridge Resistance
Ω
700
Protection According to EN 60529
IP67 or higher
(*) 2-3dBm; Telemetry range will change according to site RF Channel Settings
(**) Battery Life changes as per RF output; latency; Temp; antenna distances etc. Refer to
Manufacturer for details.
Содержание CCWR
Страница 1: ...Doc No 0096489 Page 1 of 29 V1 2 Issued 17 Aug 2020 User Manual CCWR...
Страница 7: ...CCWR User Manual Doc No 0096489 Page 7 of 29 V1 2 Issued 17 Aug 2020 Enclosure Mounting...
Страница 17: ...CCWR User Manual Doc No 0096489 Page 17 of 29 V1 2 Issued 17 Aug 2020 Channel Selector Switch...
Страница 29: ...CCWR User Manual Doc No 0096489 Page 29 of 29 V1 2 Issued 17 Aug 2020 13 CCWR Control Drawing 0090977...