3
© 2016 OJ Electronics A/S
Type FLP35-120/240GA
English
11
Press the
OK
button. The symbol for the next event (e.g. at
work) will now flash, allowing you to set the time and tempera-
ture for this period of the day by repeating steps 6-12.
12
Once time and temperature have been set for the four events
applicable for the 5-day period Monday to Friday,
Exit
will flash.
13
Press the
OK
button. The next 2 days,
Sat Sun
, will then flash.
Please note that now only two events (Day and Night) are dis-
played.
14
Press the
OK
button. The symbol for the first event will flash.
15
Set the time and temperature for this event, and for the following
event, by repeating steps 6-12.
16
Finally, select
Exit
to exit the
Program
for the 5:2 schedule.
PROGRAM
SAT SUN
EXIT
SET TEMP
Quick Set Temperature
I want to permanently change the temperature for the
event currently active in the automatic program.
To do so, you must use the override mode:
1
Press the
Up
or
Down
buttons to set the required temperature
for the event currently active.
2
Press the
OK
button.
The new temperature setting will then be saved and used for this
event in the future.
Example: If you change the temperature on a Tuesday morning
while the thermostat is running a 5:2 program, the new tempera-
ture will apply to all mornings from Monday to Friday.
Adaptive Function
I want to ensure that the required temperature has
already been reached when I get up in the morning or
come home from work.
To do so, you must activate the adaptive function:
1
Press the
OK
button to activate the menu.
2
Press the
Up
or
Down
buttons until the
Settings
option flashes.
3
Press the
OK
button.
4
Press the
Up
or
Down
buttons until the
Adaptive
option flashes.
5
Press the
OK
button. On or Off will now flash in the upper part
of the display.
6
Press the
Up
or
Down
buttons until
On
flashes.
7
Press the
OK
button.
8
Select
Exit
to exit the option.
Please note:
The adaptive function is only related to the 4-event
program and only works in connection with going from one event to
another where the temperature is going to be raised.
The adaptive function calculates when the thermostat must start
the heating system to ensure that the required temperature is
reached at the set time. Three days after the adaptive function has
been activated, it has learned when the heating must be switched
on to attain the required temperature.
SETTINGS
TIME
DAY
CHILDLOCK
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT
Manual Mode
I want to temporarily cancel the automatic 4-event
program and manually select temperature.
To do so, you must use manual mode:
1
Press the
OK
button to activate the menu.
2
Press the
Up
or
Down
buttons until the
Mode
option flashes.
3
Press the
OK
button.
4
Press the
Up
or
Down
buttons until
Man. mode
flashes in the
upper part of the display. The temperature will begin to flash.
5
Press the
Up
or
Down
buttons until the required temperature
flashes.
6
Press the
OK
button.
Please note:
This feature can be useful for instance if you are go-
ing on holiday and want to maintain a frost protection temperature
(e.g. 41 °F) while you are away.
To return to the automatic 4-event program, you must select Auto.
Please refer to page 2 for instructions.
MAN. MODE
MODE
Temporary Override
I want to temporarily set a comfort temperature for a
single event, e.g. because I am not at work one day and
want to maintain a higher temperature or because I am
having a party.
To do so, you must use the override mode:
1
Press the
OK
button twice to activate the menu.
2
Press the
Up
or
Down
buttons until the
Mode
option flashes.
3
Press the
OK
button.
4
Press the
Up
or
Down
buttons until
Override
flashes in the up-
per part of the display. The temperature will begin to flash.
5
Press the
Up
or
Down
buttons until the required temperature
flashes.
6
Press the
OK
button.
Fact
or
y setting: ON
AM