OPERATION
Use the switch in front of the light head to turn on/off.
Installation suggestion:
FLX3M
and
FLX3C
come with stick pads to increase the performance of magnet or c-clamp. Remove
protection before installing your FLEXLITE definitively.
SAFETY ADVICE
If the light head becomes too hot, an integrated electronic device will turn the light power down to 25% of
efficiency on blinking mode. If the temperature still increases, the device will cut the light off automatically.
Verify if the heat sink is clean. If the problem persists, return the work light to an authorized service center.
When the battery becomes discharged, the light head will automatically turn the light power down to 25% of
efficiency to allow the user several minutes to leave the dark area.
MAINTENANCE
WARNING:
When servicing use only identical
FLEXLITE
replacement parts. Use of any other parts may create hazards or
cause product damage.
Always wear safety goggles or safety glasses with side shields when using compressed air to clean work lights. If
operation is dusty, also wear a dust mask.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most plastics are susceptible to damage from various types of commercial
solvents and may be damaged by their use. Use clean cloth to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline, petroleum-based products, penetrating oils, etc., come in contact with
plastic parts. Chemicals can damage, weaken or destroy plastic which may result in serious personal injury.
FAN AND /OR HEATSINK MAINTENANCE
The FLX3M / FLX3C model is made with an integrated cooling fan. Designed to resist rain and dust. This fan and air
flow heat sink must be cleaned frequently to perform. Use only a
low air pressure
gun to clean and remove any dust.
Don’t use solvent, soap or cleaner. The unit is clean when you can see across the heat sink.
WARNING:
Do not immerse in water.