5 Vacuum unit CV 200 / CV 300 / CV 400 RRC assembly instructions
5.1 Fitting the mounting bracket
Plan the positioning of the mounting bracket so that there is plenty
of space above and below the area where the vacuum unit is to
be located. Make sure there is a minimum of 400 mm free space
below the dust container.
Mark the positions for all four screw holes with a pen or similar.
The diameter of the holes in the holder is 5 mm. Select screws
and, if necessary, wall plugs suitable for the type of wall concer-
ned. Drill the four screw holes.
Fit the mounting bracket with the large opening pointing down-
wards, see Fig. 14. Then screw the holder fi rmly into place.
5.2 Locating the vacuum cleaner on
the mounting bracket
To facilitate the procedure, fi rst remove the dust container. Free
the container by pulling both handles outwards. Then remove the
container from the machine. To mount the vacuum cleaner/motor
chassis to the wall bracket - just lower the chassis downwards so
that the locking device of the bracket will pass through the slot of the
chassis Fig. 15. Make sure the corresponding bracket on the mac-
hine is held fi rmly in place by the wall bracket.
When removing the motor chassis from the wall bracket - push the
locking device towards you so it will release the chassis and then lift
the chassis up from bracket.
5.3 Connecting the machine
Warning: If the pipe system in your home has a different diameter
from a standard Flexit pipe system, you can buy an adapter from
a retail outlet. The Flexit pipe system has an external diameter of
51 mm.
The machine is connected with the fl exible suction hose in the lo-
wer position and the exhaust pipe uppermost, Fig 16. The fl exible
hose is connected to the dust inlet at the container of the cleaner.
Push the hose in to the inlet of the cleaner until the hose locks.
The accompanying rubber sleeve is used for tightening/loosening
purposes between the pipe system and the fl exible vacuum hose.
Feed half the length of the sleeve into the vacuum hose and fold
the other half over. Then feed 5-10 mm of the vacuum hose into the
pipe system and fold the sleeve back so that it envelopes the tail
pipe. Press the button on the hose inlet downwards in order to rem-
ove the suction hose. The fl exible suction hose acts as an adapter
connecting the vacuum unit with the pipe system.
NB! This connection must not be glued in case the unit is serviced.
Position the central vacuum cleaner so that the exhaust pipe can
be kept as short as possible, max. 5 metres. Take the surround-
ings into consideration when positioning the exhaust. For this rea-
son, you should always fi t a muffl er.
For additional information concerning the assembly and instal-
lation of the pipe system and low-current lead, please refer to the
separate assembly instructions supplied with the pipe package.
Push the hose in to the inlet at the cleaner until the hose locks.
Press the button on the hose inlet downwards in order to remove the
suction hose.