61
2.1 Fitting the wall bracket
Position the holder so that there is plenty of space above
and below the place where the vacuum unit is to be located.
Make sure there is a minimum of 500 mm free space above
the CV 100 container. Mark the positions for the four screw
holes with a pen or similar. Then select appropriate screws
and, if necessary, wall plugs for the type of wall surface to
which the bracket is to be attached. Drill the four holes for the
wall bracket. The diameter of the screw holes in the holder
is 5 mm. Fit the wall bracket with the large opening pointing
upwards, see Fig. 1. Tighten the screws so that the bracket is
held fi rmly in place (screws provided).
2.3 Connecting the machine
The machine is connected with the suction pipe in the uppermost position and
the exhaust pipe in the lower position.
This connection should not be glued but can be taped when the unit is serviced
at a later date. The suction pipe socket can be fi tted to two different points
depending on the direction in which you would like to install the pipe system.
To relocate the suction pipe socket, you need to do the following:
1. Release the suction pipe socket by unscrewing the four combination Torx screws
with a Torx T20 or an ordinary screwdriver, Fig. 3.
2. Pull the socket out of the machine, see Fig. 4.
3. Loosen the plug blanking off the outlet to which you intend moving the suction
pipe socket. Unscrew the four combination Torx screws. Remove the blanking plug
from the machine.
4. Adapt (move) the suction pipe socket to the new outlet. NB! The socket is marked ”Up”.
Make sure the socket is fi tted with ”Up” uppermost. Fasten the socket by fi tting and tightening the four screws, Fig. 5.
5. Fit the blanking plug to the outlet previously occupied by the suction pipe socket. Use the four screws to hold it in
place. The exhaust pipe must be fi rmly attached to the wall to ensure its connection with the socket does not loosen.
Remember that you will need to be able to turn the bent pipe in different directions to ensure a suitable pipe layout.
Then connect up the exhaust pipe and muffl er, Fig 6. Fit the central vacuum cleaner so that the exhaust pipe is as
short as possible, max. 5 metres. Take the surroundings into consideration when positioning the exhaust. For this
reason, you should always fi t a muffl er.
For additional information concerning the assembly and installation of the pipe system and low-current lead, please
refer to the separate assembly instructions supplied with the pipe package.
2 Vacuum unit CV 100 assembly instructions
2.2 Locating the vacuum cleaner on the
wall bracket
Position the vacuum unit so that the mounting bracket is di-
rectly above the wall bracket, see Fig. 2. Lower the machine
down on to the wall bracket. Make sure the corresponding
bracket on the machine is held fi rmly in place by the wall
bracket.
Fig. 1
Fig. 2
Fig. 3
Exhaust
Inlet
Fig. 6
Fig. 4
Fig. 5
EN
Содержание CV 100
Страница 73: ...73 ...
Страница 74: ...74 ...
Страница 75: ...75 ...
Страница 76: ...Flexit AS Televeien 15 N 1870 Ørje Norway www flexit no ...