• Position the metal spring (if mounted) and the tension strap clamp (see Fig. 7.38):
– on a horizontal pipe, mount the tension strap clamp on the side of the pipe, if possible
– mount the metal spring (if mounted) on the opposite side of the tension strap clamp.
• Insert the long end of the tension strap into the second slot of the tension strap clamp (see Fig. 7.38 a).
• Tighten the tension strap and bend it.
• Bend both ends of the tension strap (see Fig. 7.38 b).
• Repeat the steps for the second tension strap. Position the tension strap at the distance s (see Fig. 7.38).
• Put the rail on the tension strap clamps.
• Use the screws to fix the rail to the tension strap clamps (see Fig. 7.39).
• Tighten the screws.
Fig. 7.36: Tension strap with tension strap clamp
Fig. 7.37: Tension strap with metal spring and tension strap clamp
Fig. 7.38: Tension strap with metal spring and tension strap clamp on the pipe
tension strap clamp
tension strap clamp
metal spring
metal spring
s
a
b
tension
strap
metal spring
s = length of the rail - 33 mm