8
O P E R A T I N G I N S T R U C TI O N S
1 )
Mount tool in the V-block assembly on the end of the B -19 assembly arm.
2 )
Check the air regulator on the rear pin of the B -19. Make sure the knob is
turned completely counter -clockwise. Do not remove the knob. Ensure it is
turned as far counter -clockwise as possible without removing it. FAILURE TO
DO SO COULD RESULT IN INJURY IF AIR IS CONNECTED PRIOR TO THIS STEP!
3 )
Connect air supply to the air filter on the rear pin of the B -19 arm.
(Air supply should be at 90 -120 psi.)
4 )
Adjust air regulator clockwise until arm counterbalances the weight of the tool .
5 )
Always wear safety glasses and use proper safety precautions when
operating this unit.
IT IS IMPERATIVE THAT THE TABLE OR MOUNTING SURFACE BE LAGGED TO THE
FLOOR AND SECURE BEFORE USING THE FLEXARM B-19.
FlexArm is not responsible for accident or injury resulting from the misuse of
this machine or for use other than originally designed and intended.
REV.000