LIMITED WARRANTY

Your new Flex-Pro pump is a quality product and is warranted for 24 months from date of purchase (proof of purchase is required).  The 
pump will be repaired or replaced at our discretion.  Pump Head and roller assembly is warrantied against damage from chemical 
attack when proper TFD (Tube Failure Detection) system instructions and maintenance procedures are followed.

 

WHAT IS NOT COVERED

Pump Tube Assemblies and rubber components – They are perishable and require periodic replacement.

Pump removal, or re-installation, and any related labor charge.

Freight to the factory, or ProSeries service center.

Pumps that have been tampered with, or in pieces.

Damage to the pump that results from misuse, carelessness such as chemical spills on the enclosure, abuse, lack of 
maintenance, or alteration which is out of our control.

Pumps damaged by faulty wiring, power surges or acts of nature.

Blue-White Industries does not assume responsibility for any loss, damage, or expense directly or indirectly related to or arising out of 
the use of its products.  Failure must have occurred due to defect in material or workmanship and not as a result of operation of the 
product other than in normal operation as defined in the pump manual.
Warranty status is determined by the pump's serial label and the sales invoice or receipt.  The serial label must be on the pump and 
legible.  The warranty status of the pump will be verified by Blue-White Industries or a factory authorized service center.

OTHER IMPORTANT WARRANTY INFORMATION

Please be advised; injection and metering devices are not intended as a means of treating water to render it suitable for human 
consumption.  When used as hypochlorinators, they are meant to destroy bacteria and algae contamination, before its removal by 
filtration.  Acid and soda injectors are used for PH control (balance).  Blue-White Industries injectors are factory tested with water only 
for pressure and performance.  Installers and operators of these devices must be well informed and aware of the precautions to be 
taken when injecting various chemicals -especially those considered hazardous or dangerous, eye protection must be worn when 
working around this product or any other metering type of pump.
Should it become necessary to return the pump for repair or service, you must attach information regarding the chemical used as some 
residue may be present within the unit which could be a hazard to service personnel.
Blue-White Industries will not be liable for any damage that may result by the use of chemicals with their injectors and its components.  
Thank you.

PROCEDURE FOR IN WARRANTY REPAIR

Contact the factory to obtain a RMA (Return Material Authorization) number. Carefully pack the pump to be repaired. It is recommended 
to include foot strainer and injection/check valve fitting since these devices may be clogged and part of the problem.  Please enclose a 
brief description of the problem as well as the original invoice or sales receipt, or copy showing the date of purchase.  Prepay all 
shipping costs.  COD shipments will not be accepted.  Warranty service must be performed by the factory or an authorized ProSeries 
service center.  Damage caused by improper packaging is the responsibility of the sender.  When In-Warranty repair or replacement is 
completed, the factory pays for return shipping to the dealer or customer.

Users of electrical and electronic equipment (EEE) with the WEEE marking per Annex IV of the WEEE Directive must not 
dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to them for the return, 
recycle, recovery of WEEE and minimize any potential effects of EEE on the environment and human health due to the 
presence of hazardous substances. The WEEE marking applies only to countries within the European Union (EU) and Norway. 
Appliances are labeled in accordance with European Directive 2002/96/EC. 
Contact your local waste recovery agency for a 

Designated Collection Facility

 in your area.

CALL 1-800-577-8111 FOR SALES AND SUPPORT

CLICK HERE TO RETURN TO WEBSITE

Содержание A2V24-GE

Страница 1: ...R SERIES A2 Operating Manual system TFD Tube Failure Detection Exclusive 2 TWO YEAR WARRANTY ProSeries Protected by Patents 7 001 153 7 284 964 4 496 295 and other patents pending Patent No 7 001 153...

Страница 2: ...s part of our stringent quality assur ance program at Blue White Industries Flex Pro TABLE OF CONTENTS Section Heading Page 1 0 Introduction 2 1 1 Available Models 3 2 0 Specifications 4 2 1 Materials...

Страница 3: ...01 1 4 220V AC A3V26 ND A2V26 NH ML Min 7 700 09 90 Feed Rate RPM 125 125 Max Speed A3 Model Numbers PSI bar 65 65 65 4 5 4 5 4 5 Max Pressure PSI bar 125 8 6 125 8 6 PSI bar 65 4 5 Max Temperature F...

Страница 4: ...0V60Hz NEMA 6 15 USA 220V50Hz CEE 7 VII EU 240V50Hz AS 3112 Australia New Zealand Duty cycle Continuous Enclosure 413 Aluminum Polyester powder coated Pump Head q Valox PBT thermoplastic Pump Head Cov...

Страница 5: ...clockwise and counter clockwise Output rates to 17 GPH 64 LPH and pressures to 125 PSI 8 6 Bar Variable speed DC motor Specially engineered tubing for long life at high pressures Meets FDA 21 CFR req...

Страница 6: ...ms are strictly for guideline purposes only Always consult an expert before installing metering pump on specialized systems Metering pump should be serviced by qualified persons only n Raise metering...

Страница 7: ...ecting chemicals that calcify such as sodium hypochlorite Duckbill may add additional back pressure to pump up to 7 psi 3 8 OD x 1 4 ID Tubing and Tri Clamp connection Models Proper eye and skin prote...

Страница 8: ...and power cables together Power Interruption This pump has an auto restart feature which will restore pump to operating state it was in when power was lost Note When in doubt regarding your electrical...

Страница 9: ...isplay will read OFF if pump has been stopped in this manner Pump will not respond to incoming input signals while in OFF state When START button is pressed pump will start according to it s previous...

Страница 10: ...s UP or DOWN arrow to scroll through your options Press START to make a selection The radio button square box is now filled in next to your selection Press DOWN arrow to scroll down to Done selection...

Страница 11: ...ay time value from 1 255 seconds must be programmed An alarm delay value of 000 seconds disables FVS system If FVS alarm occurs pump will stop send an external signal if setup and screen will flash FV...

Страница 12: ...d select no and press enter Turn on the pump press start If the TFD system detects the chemical the pump will stop after a two second confirmation period and the TFD Alarm screen will display If the T...

Страница 13: ...angements to allow back flow If your desire is to simply extend tube life Typically tubing fails on outlet side pressure side of tube assembly in pump head Failure to install checkvalves in their prop...

Страница 14: ...Head and Rotor Rotor can be removed by pulling straight out After cleaning process push Rotor back on shaft See drawing above for proper assembly IMPORTANT Rotor direction the word FRONT on Rotor mus...

Страница 15: ...parts are being attacked and replace them with parts that have been manufactured using more suitable materials Manufacturer does not assume responsibility for damage to pump that has been caused by c...

Страница 16: ...le directing tube into pump head At this point you may need to pull Tube Installation Tool to stretch tubing into position Let rotor spin a few rotations while pulling Installation tool so fitting can...

Страница 17: ...able with single roller assembly rotor Tubing in this group are interchangeable with single roller assembly rotor Tygothane Stainless Steel extended mounting bracket kit pair Rubber feet 72000 380 900...

Страница 18: ...with water only for pressure and performance Installers and operators of these devices must be well informed and aware of the precautions to be taken when injecting various chemicals especially those...

Отзывы: