11.0  TFD (Tube Failure Detection)

Flex-Pro is equipped with a 

Tube Failure Detection 

System which is designed to 

stop the pump and provide an output alarm (see Output menu) in the event pump 
the tube should rupture and chemical enters the pump head. The pump will 
detect a chemical with a conductivity reading greater than 500 microsiemens. 
Chemicals with a conductivity of less than 500 microsiemens will not be 
detected.

This patented system is capable of detecting the presence of a large number of 
chemicals including Sodium Hypochlorite (Chlorine),  Hydrochloric (muriatic) 
Acid, Sodium Hydroxide, and many others. The system will not be triggered by 
water (rain, condensation, etc.) or silicone oil (roller and tubing lubricant).

If system has detected chemical, pump tube must be replaced and pump head 
and roller assembly must be thoroughly cleaned.  Failure to clean the roller 
assembly will void warranty.

If TFD alarm occurs, pump will stop, close an alarm output, and screen will flash 
TFD with an alarm icon.

Confirm Chemical Detection - 

To determine if your chemical will be detected by 

the system, remove the pump head cover and the pump tube and roller assem-
bly. Place a small amount of chemical in the bottom of the pump head - just 
enough to cover the sensors. Replace the pump head cover only. When asked if 
the tube was replaced, select “no” and press enter. Turn on the pump (press 
start). If the TFD system detects the chemical, the pump will stop after a two 
second confirmation period and the TFD Alarm screen will display. If the TFD 
system does not detect the chemical, the pump will continue to run after the 
confirmation period. Carefully clean the chemical out of the pump head being 
sure to remove all traces of the chemical from sensor probes. Replace the roller 
assembly and tubing. Replace the pump head cover. Press the START button to 
clear the alarm condition and restart the pump.

Chemical from tube failure

10.0  Pump Tube Timer

Flex-Pro has a built in Pump Tube Timer. Timer starts when rotor is rotating and stops 
when rotor is idle. To view current Pump Tube Timer value, press the  START and 
DOWN buttons and the Tube Timer screen will appear. Screen will display current 
Pump Tube Time in run-time hours. The Tube Timer screen will display for 4 seconds 
and then switch back to the previous operating display screen.

While displayed, press DOWN arrow button twice to reset Pump Tube Timer to zero.

When replacing pump tube, pump will ask you if you’d like to reset Pump Tube Timer. 
If you choose YES, screen will display current Pump Tube Time for 5 seconds before 
timer is reset to zero.

12.0     Alarm Relay

Pump has a built in 6 amp alarm output relay. Relay is pre-configured to 
energize on tube failure detection (TFD) and on Flow Verification Sensor (FVS). 

A Flow Verification Sensor must be installed and configured for relay to trigger 
on no-flow conditions.

E

CALL 1-800-577-8111 FOR SALES AND SUPPORT

CLICK HERE TO RETURN TO WEBSITE

Содержание A2V24-GE

Страница 1: ...R SERIES A2 Operating Manual system TFD Tube Failure Detection Exclusive 2 TWO YEAR WARRANTY ProSeries Protected by Patents 7 001 153 7 284 964 4 496 295 and other patents pending Patent No 7 001 153...

Страница 2: ...s part of our stringent quality assur ance program at Blue White Industries Flex Pro TABLE OF CONTENTS Section Heading Page 1 0 Introduction 2 1 1 Available Models 3 2 0 Specifications 4 2 1 Materials...

Страница 3: ...01 1 4 220V AC A3V26 ND A2V26 NH ML Min 7 700 09 90 Feed Rate RPM 125 125 Max Speed A3 Model Numbers PSI bar 65 65 65 4 5 4 5 4 5 Max Pressure PSI bar 125 8 6 125 8 6 PSI bar 65 4 5 Max Temperature F...

Страница 4: ...0V60Hz NEMA 6 15 USA 220V50Hz CEE 7 VII EU 240V50Hz AS 3112 Australia New Zealand Duty cycle Continuous Enclosure 413 Aluminum Polyester powder coated Pump Head q Valox PBT thermoplastic Pump Head Cov...

Страница 5: ...clockwise and counter clockwise Output rates to 17 GPH 64 LPH and pressures to 125 PSI 8 6 Bar Variable speed DC motor Specially engineered tubing for long life at high pressures Meets FDA 21 CFR req...

Страница 6: ...ms are strictly for guideline purposes only Always consult an expert before installing metering pump on specialized systems Metering pump should be serviced by qualified persons only n Raise metering...

Страница 7: ...ecting chemicals that calcify such as sodium hypochlorite Duckbill may add additional back pressure to pump up to 7 psi 3 8 OD x 1 4 ID Tubing and Tri Clamp connection Models Proper eye and skin prote...

Страница 8: ...and power cables together Power Interruption This pump has an auto restart feature which will restore pump to operating state it was in when power was lost Note When in doubt regarding your electrical...

Страница 9: ...isplay will read OFF if pump has been stopped in this manner Pump will not respond to incoming input signals while in OFF state When START button is pressed pump will start according to it s previous...

Страница 10: ...s UP or DOWN arrow to scroll through your options Press START to make a selection The radio button square box is now filled in next to your selection Press DOWN arrow to scroll down to Done selection...

Страница 11: ...ay time value from 1 255 seconds must be programmed An alarm delay value of 000 seconds disables FVS system If FVS alarm occurs pump will stop send an external signal if setup and screen will flash FV...

Страница 12: ...d select no and press enter Turn on the pump press start If the TFD system detects the chemical the pump will stop after a two second confirmation period and the TFD Alarm screen will display If the T...

Страница 13: ...angements to allow back flow If your desire is to simply extend tube life Typically tubing fails on outlet side pressure side of tube assembly in pump head Failure to install checkvalves in their prop...

Страница 14: ...Head and Rotor Rotor can be removed by pulling straight out After cleaning process push Rotor back on shaft See drawing above for proper assembly IMPORTANT Rotor direction the word FRONT on Rotor mus...

Страница 15: ...parts are being attacked and replace them with parts that have been manufactured using more suitable materials Manufacturer does not assume responsibility for damage to pump that has been caused by c...

Страница 16: ...le directing tube into pump head At this point you may need to pull Tube Installation Tool to stretch tubing into position Let rotor spin a few rotations while pulling Installation tool so fitting can...

Страница 17: ...able with single roller assembly rotor Tubing in this group are interchangeable with single roller assembly rotor Tygothane Stainless Steel extended mounting bracket kit pair Rubber feet 72000 380 900...

Страница 18: ...with water only for pressure and performance Installers and operators of these devices must be well informed and aware of the precautions to be taken when injecting various chemicals especially those...

Отзывы: