Installation, Operation & Maintenance Guide
Style 58
REMOVING THE SEAL
•
Before opening the pump to remove the seal the warning stated above regarding toxins and
hazardous products must be reiterated. Make note of all fluids contained in the pump, drain
and decontaminate before opening the housing for seal service.
1
. Ensure all fluid has been drained and vented. Equipment should be shut down and locked/tagged out
according to OEM and plant specifications.
2
. Dismantle equipment sufficiently so that the gland plate and seal housing are exposed and accessible for
service.
3
. Reset the setting clips that were saved from installation.
4
. Back-out the cup point set screws.
5
. Remove the gland bolts/nuts in an even manner.
6
. Carefully slide the seal out and off of the shaft.
If a part is going to be returned for service or to any third party, all shipments should have
appropriate safe-handling instructions securely attached to the package.
[F]
[D]
[V]
Figure 8: Style 58A with multipoint injection and a floating carbon throttle bushing.
Page 6 of 6