Fleet Management MLT-400i Скачать руководство пользователя страница 8

MLT-400i Installation Guide 

 

Securing the Unit 

 

11/18/2009 

FMS MLT-400i Installation Guide 4.3 

MLT-400i/400iO I/O Connection 

Note, when installing the modem, leaving easy access to the serial cable will facilitate any 
code updates. 

If additional I/O connections are desired for analog/digital inputs or digital outputs, the wire 
harness is defined below.  

 

MLT-400i Wire Harness Description 

Wire Color  Use 

Operating Range 

Red 

*

 

Constant power source. Not accessory power.  

9-30VDC 

Black 

Chassis Ground 

Ground 

Green 

*

 

True Ignition Source 

9-30VDC 

Purple

 

*

 

Signal Ground. Connect at analog sensor’s ground. 

Ground 

Orange 

*

 

Analog/Digital IN # 0 

0-5VDC 

Brown 

*

 

Analog/Digital IN # 1 

0-5VDC 

Grey 

*

 

Analog/Digital IN # 2 

0-5VDC 

Blue 

*

 

Digital IN     # 0 

3-30VDC 

Yellow 

*

 

Digital OUT # 1 

12VDC, 50mA 

White 

*

 

Digital OUT # 2 

12VDC, 50mA 

Notes: 

 

Cap Off any sensors not being used. 

 

 

 

Securing the Unit 

1.

 

Before securing the unit, typically under the dashboard, record the IMEI/Serial Number 
(ESN), Vehicle Name (Asset Name), Odometer and if available Engine Hours on the 
Installation Checklist in Appendix B. 

2.

 

Use tie-wraps to mount the unit securely to a stable bracket. 

3.

 

If possible, orient the unit so the LED indicators are visible. 

4.

 

Do not place the unit near moving parts, or next to any of the vehicle’s pedals 

5.

 

Loosely bundle any excess antenna cable, power wiring and unused I/O signals 

6.

 

Leaving easy access to the 9-pin serial cable will allow for code updating. 

 

 
 

 

 

 
 

Содержание MLT-400i

Страница 1: ...MLT 400i Installation Guide 11 18 2009 FMS MLT 400i Installation Guide 4 3 1...

Страница 2: ...tion Requirements Fleet Management Solutions recommends that you contact a professional installation provider Please contact FMS for an approved installation provider list or to arrange in stallation...

Страница 3: ...Safety Considerations 5 Determine the Best Location 5 Connect Power Ignition and I O 6 MLT 400iO OBDII Connection 6 MLT 400i Three Wire Connection 6 MLT 400i 400iO I O Connection 8 Securing the Unit 8...

Страница 4: ...ndard and Metric socket set Screwdrivers standard Phillips Hex Torx Recommended Supplies sealant screws e for tamper Installation Checklist to capture required installation and system alidation inform...

Страница 5: ...ridium cable connects to the MLT 400i Iridium cable they are color coded blue and black respec tively Apply inspection torque seal if desired see below Check antenna cable length will reach to desired...

Страница 6: ...ection The MLT 400i is shipped with one in line 2 amp fuse attached to the power cable This fuse should be installed as close as possible to the primary 12 or 24 volt source connection If the power co...

Страница 7: ...Wire True Ignition Attach the green wire to true ignition source of 9 to 30 volts DC Do not connect to accessory power To determine true ignition 1 Select a wire 2 With the key OFF use a voltmeter to...

Страница 8: ...nalog Digital IN 0 0 5VDC Brown Analog Digital IN 1 0 5VDC Grey Analog Digital IN 2 0 5VDC Blue Digital IN 0 3 30VDC Yellow Digital OUT 1 12VDC 50mA White Digital OUT 2 12VDC 50mA Notes Cap Off any se...

Страница 9: ...s ignition wiring and type and the optional Ignition Enable Disable feature Validate Communications with Fleet Central If you don t have access to the FMS Fleet Central web application please call FMS...

Страница 10: ...wap unit with a known good vehicle installation Verify antenna installation Verify that the unit is activated 4 No LED activity on MLT 400iO OBDII Blown fuse powering OBDII connector The OBDII fuse ty...

Страница 11: ...holes use Heyco 1675 black or 1676 white for use when removing antenna Use hole template below as a drill guide Check printed tem plate is sized to 1 660 between holes as dimensioned on the template T...

Страница 12: ...MLT 400i Installation Guide Appendix A ANTIR01 Antenna Installation 11 18 2009 FMS MLT 400i Installation Guide 4 3 12...

Страница 13: ...se Plate Number MFG Model Vehicle Color State Driver Name Driver Position Elec Mech Safety etc Odometer Diesel or Gas Office Reports to Misc Superintendant s Name Assigned to __________ etc Date Insta...

Страница 14: ...Engine Hours if available This information will be entered into Fleet Central during the validation phase Contact FMS Technical Support at 800 999 2169 Phase 1 Installation Information Phase 2 Valida...

Отзывы: