Fleet Management MLT-400i Скачать руководство пользователя страница 6

MLT-400i Installation Guide 

 

Connect Power, Ignition and I/O 

 

Connect Power, Ignition and I/O 

Two versions of the MLT-400i are available (check the product label located on the back of 
the unit to determine which one you have): 1) the MLT-400iO is OBDII compatible; 2) the 
standard MLT-400i uses a three-wire connection. Both are described below.  

MLT-400iO OBDII Connection 

 

Ensure your vehicle is OBDII com-
patible, read the FMS OBDII “How 
to Determine Compatibility” 
available for download on Fleet 
Central from 
Admin|Support|UserGuides 

 

 

Connect the right angle OBDII 
connector in to the vehicle OBDII 
connector 

 
 
 
 
 

 

The OBDII connector may be 
located behind a panel, check your 
vehicle documentation for the 
location 

 

 

After installation validation, tie wrap 
the connectors together, if possible, 
and add a dot of inspection/torque 
seal to detect tampering 

 

 

 

If your vehicle is not OBDII com-
patible, you can still use the modem 
with the Three-Wire Connection 
below. See inset below on Using the 
MLT-400iO in Three-Wire Mode. 

 

MLT-400i Three-Wire Connection  

The MLT-400i is shipped with one in-line 2-amp fuse attached to the power cable. This fuse 
should be installed as close as possible to the primary 12 or 24 volt source connection. If the 
power connection is more that 1-2 feet from the fuse an additional fuse must be added as 
close to the power connection as possible should a short occur in the wiring. If a fuse is 
added or replaced, it should be of the same type as originally supplied from the factory. The 
original fuses supplied is one (2 Amp ATC BUSS fuse).  
Use care when routing the power cable. Route the cables where they will be protected and 
use commonly accepted install practices for aftermarket automotive electronic devices.  

 

Using The MLT-400iO in Three-Wire Mode 

 

Disconnect the OBD-II connector and attach ignition and power wires, (see MLT-400i 

Three-Wire Connection above for more details)

 

Contact FMS Technical Support to issue the Reset Configuration Command 

 

If you are using a Message Display Terminal (MDT-PRO), you must also connect both 
the modem AND the MDT (using the white two pin connector) to the same power source 

in addition to performing the steps above. 

 

 

Solder your connections (see Poke and Wrap below)  

11/18/2009 

FMS MLT-400i Installation Guide 4.3 

Содержание MLT-400i

Страница 1: ...MLT 400i Installation Guide 11 18 2009 FMS MLT 400i Installation Guide 4 3 1...

Страница 2: ...tion Requirements Fleet Management Solutions recommends that you contact a professional installation provider Please contact FMS for an approved installation provider list or to arrange in stallation...

Страница 3: ...Safety Considerations 5 Determine the Best Location 5 Connect Power Ignition and I O 6 MLT 400iO OBDII Connection 6 MLT 400i Three Wire Connection 6 MLT 400i 400iO I O Connection 8 Securing the Unit 8...

Страница 4: ...ndard and Metric socket set Screwdrivers standard Phillips Hex Torx Recommended Supplies sealant screws e for tamper Installation Checklist to capture required installation and system alidation inform...

Страница 5: ...ridium cable connects to the MLT 400i Iridium cable they are color coded blue and black respec tively Apply inspection torque seal if desired see below Check antenna cable length will reach to desired...

Страница 6: ...ection The MLT 400i is shipped with one in line 2 amp fuse attached to the power cable This fuse should be installed as close as possible to the primary 12 or 24 volt source connection If the power co...

Страница 7: ...Wire True Ignition Attach the green wire to true ignition source of 9 to 30 volts DC Do not connect to accessory power To determine true ignition 1 Select a wire 2 With the key OFF use a voltmeter to...

Страница 8: ...nalog Digital IN 0 0 5VDC Brown Analog Digital IN 1 0 5VDC Grey Analog Digital IN 2 0 5VDC Blue Digital IN 0 3 30VDC Yellow Digital OUT 1 12VDC 50mA White Digital OUT 2 12VDC 50mA Notes Cap Off any se...

Страница 9: ...s ignition wiring and type and the optional Ignition Enable Disable feature Validate Communications with Fleet Central If you don t have access to the FMS Fleet Central web application please call FMS...

Страница 10: ...wap unit with a known good vehicle installation Verify antenna installation Verify that the unit is activated 4 No LED activity on MLT 400iO OBDII Blown fuse powering OBDII connector The OBDII fuse ty...

Страница 11: ...holes use Heyco 1675 black or 1676 white for use when removing antenna Use hole template below as a drill guide Check printed tem plate is sized to 1 660 between holes as dimensioned on the template T...

Страница 12: ...MLT 400i Installation Guide Appendix A ANTIR01 Antenna Installation 11 18 2009 FMS MLT 400i Installation Guide 4 3 12...

Страница 13: ...se Plate Number MFG Model Vehicle Color State Driver Name Driver Position Elec Mech Safety etc Odometer Diesel or Gas Office Reports to Misc Superintendant s Name Assigned to __________ etc Date Insta...

Страница 14: ...Engine Hours if available This information will be entered into Fleet Central during the validation phase Contact FMS Technical Support at 800 999 2169 Phase 1 Installation Information Phase 2 Valida...

Отзывы: