Printed in U.S.A.

Page 6B

MODEL 6700 Downflow - V2.0

Option Setting Level #2

Softener Manufacturer Programming (Cont’d.)

9.

Timed Auxiliary Output Window #2 Setting (r)

Depress the Program Button. This option setting 
consists of two displays. The first display is used to 
set the turn on time of the output, referenced to the 
start of Backwash. The second display is used to set 
the output turn off time, referenced again to the start 
of Backwash. An OFF setting cancels this setting. A 
set on time with a set off time of S will turn the output 
off at the start of Service. All settings are in minutes 
and output timing is synchronized with regeneration 
cycle timing.

Examples: Activate output 15 min. after the start of 
Step #1/Deactivate when in Service -[r - - - 15.0]

[- - - - - - S]
Cancel setting - [r - - -OFF]

The UP and DOWN Set Buttons will adjust this 
value.

10. Chemical Pump Output (n)

Depress the Program Button. This option setting 
consists of two displays. The first display is used to 
set the turn on time (in minutes) of the output. The 
second display is used to set the volume of water flow 
at which the output will turn on.

Examples: Activate output 1.0 min. after every 200 
gallons -[n - - - - 1.0]
[          200]

Activate output 1 second after every 200 gallons -[n - 
- - - - P] 
(Pulse Mode)
[          500]
Cancel setting -[n - - - OFF]

The UP and DOWN Set Buttons will adjust these 
settings.

11. Regeneration Day Override (A)

Depress the Program Button. The next display is used 
to set the Regeneration Day Override Option Setting. 
The Regeneration Day Override Option Setting sets 
the maximum amount of days that the conditioner can 
be in service without a regeneration, regardless of 
water usage or the lack of a sensor signal. 
Regeneration begins at the set regeneration time or 
at the previous regen time. An OFF setting will cancel 
this option with all regeneration types except Time 
Clock Regeneration. A day override setting is 
required for time clock regeneration valves.

Examples: 

Override every 7 days -

[A - - - 

- - 7]

Cancel Setting -

[A - - -

OFF]

The UP and DOWN Set Buttons will adjust this 
value.

12. Volume Override (b)

Depress the Program Button. The next display viewed 
is used to set the maximum amount of water that can 
be used before a regeneration cycle is called for. 
When this feature is used with delayed regeneration 
systems, it will be up to the programmer to determine 
a reserve capacity. The control will no longer keep 
track of the reserve capacity. This option is typically 
used to bypass standard reserve or capacity 
calculations made by the control.

Examples: 

Override every 700 gallons -

[b - - - 

700]

Override cancelled -

[b - - -

OFF]

The UP and DOWN Set Buttons adjust this value.

Содержание 6700 Downflow

Страница 1: ...P 10 Note This display only viewed with metric display formats U2 U4 System Capacity Example 20 000 Grain Capacity 20 Regeneration Time Example 2 00 A M 2 00 Regeneration Cycle Step 1 Backwash Exampl...

Страница 2: ...entified by the red LED next to the Water Hardness label Example 25 grains 25 The UP and DOWN Set Buttons will adjust this value 2 Water Hardness After Mixing Valve P Depress the Program Button The ne...

Страница 3: ...lue 25 gpm or black 5 gpm rate of refill in gpm times your timer setting Then using one gallon of fresh water dissolving approximately 3 lbs of salt calculate your refill time Valves equipped for Vari...

Страница 4: ...lay Example 5 Days d 5 Prior Service Volume Used Display Example 858 Gallons E 858 Reserve Capacity Display Example 158 Gallons rc 158 Previous Days Water Usage Display Example 258 Gallons Pd 258 Cycl...

Страница 5: ...Or Valves Without Meters Chemical Pump Output Volume Count Setting Example Turn On In Service Every 100 Gallons 100 Regeneration Day Override Example Override Every 7 Days A 7 Volume Override Example...

Страница 6: ...lly Used F 3 Option Not Typically Used F 4 Option Not Typically Used F 5 Option Not Typically Used F 6 Mixing Valve Location Examples No Mixing Valve 8 1 Mixing Valve Before Flow Meter 8 2 Mixing Valv...

Страница 7: ...s Depending on current pro gramming certain displays or option settings will not be viewed 1 Flow Rate Display Fr The first display viewed is the current flow rate of treated water through the softene...

Страница 8: ...tual control of power to a chlorinator is handled independently of this setting using a microswitch or Timed Auxiliary Output Examples No Chlorinator Installed J OFF Chlorinator to turn on during Step...

Страница 9: ...r every 200 gallons n P Pulse Mode 500 Cancel setting n OFF The UP and DOWN Set Buttons will adjust these settings 11 Regeneration Day Override A Depress the Program Button The next display is used to...

Страница 10: ...be P P M mg liter or g m3 and Capacity in grams Regeneration Types 7 and 8 will not be displayed Example U 4 The Japanese Metric Format uses liters for volume and liters per minute for flow rate relat...

Страница 11: ...will only be able to be viewed when this option selected Example 7 5 Initial Display Sensor Input Signal Minimum On Time 7 5 5 0 5 0 Minutes Sensor Delayed The control will monitor conditioner status...

Страница 12: ...d 9 9 Option Not Typically Used The UP and DOWN Set Buttons will adjust this value 19 Program Lock PL Depress the Program Button The display is used to prevent certain displays from being viewed or se...

Отзывы: