MODEL 6700 Downflow - V2.0
Option Setting Level #2
Softener Manufacturer Programming
Manufacturing of the softener requires access to the
second level of option programming.
This level includes the functioning parameters of the
softener, related to actual system configuration.
Entering Option Level #2
Depress the Program Button for 5 seconds. The Program
Arrow will turn on and the first display v iewed is used to
set the Inlet Water Hardness. Next, depress the Extra
Cycle Button for 5 seconds. Depending on current pro-
gramming, certain displays or option settings will not be
viewed.
1.
Flow Rate Display (Fr)
The first display viewed is the current flow rate of
treated water through the softener.
The unit of measurement used is gallons/liters per
minute.
Example: 8.5 gallons per minute - [F - - - 8.5]
2.
Days Since Last Regeneration Display (d)
Depress the Program Button. The next display viewed
is not an option setting. This display is used as an aid
to the service person in diagnosing a valve
malfunction. The number of days since the last
regeneration is recorded by the control in this display.
Example: 4 days - [d - - - - - 4]