MODEL 6700 Downflow - V2.0
Option Setting Level #1
Installer Programming
Setting up the valve during installation requires
access to the first level of option programming.
Entering Option Level #1
Depress the Program Button for 5 seconds. The Program
Arrow will turn on and the first display v iewed is used to
set the Inlet Water Hardness. Depending on current pro-
gramming, certain displays or option settings will not be
viewed.
1.
Water Hardness
The unit of measure used for this setting is grains/
French degrees/P.P.M./German degrees. This option
setting is identified by the red LED next to the Water
Hardness label.
Example: 25 grains [ 25]
The UP and DOWN Set Buttons will adjust this
value.
2.
Water Hardness After Mixing Valve (P)
Depress the Program Button. The next display viewed
is the option setting for water hardness after mixing
valve. This option setting is identified by the letter P
only. The unit of measure used for this setting is
French degrees or P.P.M. This display will only be able
to be viewed with U.S./metric Display Format set to
either metric formats. This option setting is used with
inlet water mixing valve equipped unit only.
Example: 10 French degrees of Hardness [P - - - - 10]
The UP and DOWN SET Buttons will adjust this
value.