MODEL 5600SE Upflow

General Residential Installation Check List

WATER  PRESSURE:  A  minimum  of  25  pounds  of  water  pressure  is  required  for  regeneration  valve  to  operate
effectively.

ELECTRICAL  FACILITIES:  An  uninterrupted  alternating  current  (A/C)  supply  is  required.    Please  make  sure  your
voltage supply is compatible with your unit before installation.

EXISTING PLUMBING: Condition of existing plumbing should be free from lime and iron buildup. Piping that is built up
heavily  with  lime  and/or  iron  should  be  replaced.  If  piping  is  clogged  with  iron,  a  separate  iron  filter  unit  should  be
installed ahead of the water softener.

LOCATION  OF  SOFTENER  AND  DRAIN:  The  softener  should  be  located  close  to  a  clean  working  drain  and
connected according to local plumbing codes.

BY-PASS VALVES: Always provide for the installation of a by-pass valve if unit is not equipped with one.

CAUTION: Water pressure is not to exceed 120 p.s.i., water temperature is not to exceed 110°F, and the unit cannot be
subjected to freezing conditions.

Valve Installation and Start-up Procedures

1.

Place the softener tank where you want to install the unit, making sure the tank is level and on a firm base.

2.

During cold weather it is recommended that the installer warm the valve up to room temperature before operating.

3.

All  plumbing  should  be  done  in  accordance  with  local  plumbing  codes.  The  pipe  size  for  the  drain  should  be  a
minimum of 1/2

. Backwash flow rates in excess of 7 gpm or length in excess of 20

 require 3/4

 drain line.

4.

The 1

 distributor tube (1.050 O.D.) should be cut 2.0

 below the top of each tank. Note: Only use silicone lubricant.

5.

Lubricate the distributor o-ring seal and tank O-ring seal. Place the main control valve on tank.

6.

Solder joints near the drain must be done prior to connecting the Drain Line Flow Control fitting (DLFC). Leave at
least 6

  between the DLFC and solder joints when soldering pipes that are connected on the DLFC. Failure to do

this could cause interior damage to DLFC.

7.

Teflon tape is the only sealant to be used on the drain fitting.

8.

Make sure that the floor is clean beneath the salt storage tank and that it is level.

9.

Place approximately 1

 of water above the grid plate. If a grid is not utilized, fill to the top of the air check in the salt

tank. Do not add salt to the brine tank at this time.

10. On  units  with  a  by-pass,  place  in  by-pass  position.  Turn  on  the  main  water  supply.  Open  a  cold  soft  water  tap

nearby and let run a few minutes or until the system is free from foreign material (usually solder) that may have
resulted from the installation. Once clean, close the water tap.

11. Place the by-pass in service position and let water flow into the mineral tank. When water flow stops, slowly open a

cold water tap nearby and let run until the air is purged from the unit. Then close tap.

12. Plug the valve into an approved power source. Once the valve is powered it will drive to the Service Position.

Содержание 5600SE

Страница 1: ...IMPORTANT Fill in pertinent information on page 2 for future reference MODEL 5600SE Upflow Brining Service Manual...

Страница 2: ...n _____________________________________________________________ Page 2 Valve Programming Treated Water Capacity ______________________________ Gallons Liters Regeneration Day Override ________________...

Страница 3: ...ing codes The pipe size for the drain should be a minimum of 1 2 Backwash flow rates in excess of 7 gpm or length in excess of 20 require 3 4 drain line 4 The 1 distributor tube 1 050 O D should be cu...

Страница 4: ...or Down Set Button once to adjust Time Of Day Display by one digit Push and hold either Up or Down Set Button to adjust Time Of Day Display by several digits 1 Set Time Of Day 1 Push and hold for 5 s...

Страница 5: ...ontrol programming is now complete Push the Extra Cycle Button This will exit the control from the Programming Mode and resume Normal Operation 1 The first option setting display that appears in the P...

Страница 6: ...tely With Delayed Regeneration controls the Service Arrow will begin to flash immediately and a regeneration will occur at the present regeneration time i e 2 00 a m 2 Press and Hold for 5 seconds the...

Страница 7: ...4 Optional With proper valve operation verified A Add water to the top of the air check Manually step the valve to the Brine Draw Position and allow the valve to draw water from the brine tank until...

Страница 8: ...on Time This event occurs regardless of the Volume Remaining display having reached zero gallons Control Operation During Regeneration In Regeneration the control will display a special Regeneration D...

Страница 9: ...Printed in U S A Page 9 MODEL 5600SE Upflow Water Conditioner Flow Diagrams Upflow Brining Using Yellow Cycle Cam Part No 24598 Service Position Backwash Position Regeneration Cycle Step 1...

Страница 10: ...n U S A MODEL 5600SE Upflow Water Conditioner Flow Diagrams Upflow Brining Using Yellow Cycle Cam Part No 24598 Cont d Regeneration Cycle Step 2 Brine Slow Rinse Position Rapid Rinse Position Regenera...

Страница 11: ...inted in U S A Page 11 MODEL 5600SE Upflow Water Conditioner Flow Diagrams Upflow Brining Using Yellow Cycle Cam Part No 24598 Cont d Regeneration Cycle Step 4 Brine Tank Fill Position Service Positio...

Страница 12: ...Page 12 Printed in U S A MODEL 5600SE Upflow Water Conditioner Flow Diagrams Upflow Brining Using Red Cycle Cam Part No 17885 Service Position Brine Slow Rinse Position Regeneration Cycle Step 1...

Страница 13: ...in U S A Page 13 MODEL 5600SE Upflow Water Conditioner Flow Diagrams Upflow Brining Using Red Cycle Cam Part No 17885 Backwash Position Regeneration Cycle Step 2 Rapid Rinse Position Regeneration Cycl...

Страница 14: ...Page 14 Printed in U S A MODEL 5600SE Upflow Water Conditioner Flow Diagrams Upflow Brining Using Red Cycle Cam Part No 17885 Brine TankFill Position Regeneration Cycle Step 4 Service Position...

Страница 15: ...U S A Page 15 MODEL 5600SE Upflow Valve Wiring Diagram CB1 5600SE Circuit Board VDM Valve Drive Motor EM Electronic Flow Meter Optional SW1 Homing Switch SW2 Step Switch HCAM Homing Cam UFSCAM Upflow...

Страница 16: ...MODEL 5600SE Upflow Control Valve Assembly See opposite page for parts list 61 60 1 2 3 4 7 6 5 11 12 13 14 18 17 16 15 10 22 23 24 28 26 25 20 29 31 39 41 42 43 44 48 47 46 45 49 51 52 53 54 58 57 5...

Страница 17: ...pecify Size 25 1 10227 Injector Screen 26 2 13301 O Ring Injector 28 1 13303 O Ring Injector Cover 29 1 13166 Injector Cover 31 2 13315 Screw 39 1 13245 BLFC Button Retainer 40 1 12977 O Ring 41 1 BLF...

Страница 18: ...Page 18 Printed in U S A MODEL 5600SE Upflow Valve Powerhead Assembly See opposite page for parts list 19 20 26 3 24 23 2 1 4 6 7 5 9 10 11 12 13 14 8 14 18 17 16 15 25 21 22 24 14 28...

Страница 19: ...PM 24V 50 60Hz 12 3 11384 Screw Motor 13 1 13229 Back Plate 14 4 13296 Screw Component 15 1 12037 Washer 16 1 18722 Cam Brine Valve 17 1 19674 Transformer 24V 9 6VA U S 120V 1 25651 Transformer 24V 9...

Страница 20: ...y Parts List Item No Quantity Part No Description 1 2 13314 Screw Hex Washer 8 18 x 5 8 2 2 19569 Clip Flow Meter 3 1 19797 Meter Body Assembly 3 4 Turbine 4 4 13305 O Ring 119 5 1 19791 01 Harness As...

Страница 21: ...A 1 17820 Plug By Pass Inlet 5B 1 17820 01 Plug By Pass Outlet White 6 4 18661 O Ring 218 7 2 18662 Retaining Ring 8 2 18660 O Ring 9 2 13305 O Ring 119 10 2 13255 Clip Mounting 11 2 13314 Screw Hex W...

Страница 22: ...ass Valve Body 3 4 1 17290NP By Pass Valve Body 3 4 Nickel Plate 1 13399 By Pass Valve Body 1 1 13399NP By Pass Valve Body 1 Nickel Plate 2 1 11726 Seal By Pass 3 1 11972 Plug By Pass 4 1 11978 Side C...

Страница 23: ...2300 Safety Brine Valve Body 2 1 10138 Ball 3 8 3 1 11566 Bull Stop 4 1 10328 Elbow 1 4 x 1 4 T 5 2 10332 Insert 3 8 6 2 10330 Sleeve 3 8 7 2 10329 Tube Nut 3 8 8 1 10186 Nut Hex 10 32 Nylon 9 1 60002...

Страница 24: ...Page 24 Printed in U S A MODEL 5600SE Upflow 2310 Safety Brine Valve See Opposite Page for Parts List...

Страница 25: ...ve Arm Assembly 3 1 19804 Stud 10 24 4 1 19805 Nut 10 24 5 1 19652 01 Poppet Seal 6 1 19649 Flow Dispenser 7 1 11183 O Ring 017 8 1 19647 Elbow Safety Brine Valve 9 2 19625 Nut Assembly 3 8 10 1 18312...

Страница 26: ...s or inlet valving to normal service position Water pressure should now be applied to the conditioner and any by pass line shut off 11 Check for leaks at all seal areas Check drain seal with the contr...

Страница 27: ...holding signal wire from meter dome 3 Remove two screws and clips at by pass valve or yoke Pull resin tank away from plumbing connections 4 Remove two screws and clips at control valve Pull meter mod...

Страница 28: ...ted Flushings of the Hot Water Tank is Required F Make Sure Distributor Tube is not Cracked Check O Ring and Tube Pilot G Replace Seals and Spacers and or Piston H Remove obstruction from flow meter I...

Страница 29: ...Control is Plugged B Injector is Plugged C Injector Screen Plugged D Line Pressure is too Low E Internal Control Leak F Improper Programming G Timer not Operating Properly A Clean Drain Line Flow Con...

Страница 30: ...1 14309 Piston Rod Retainer 1 13001 03 Piston Rod Assembly 1 15561 End Plug Assy White 1 18848 Piston Upflow 60125 5600SE Seal and Spacer Kit For Illustration and Parts List See Pages 16 and 17 5 1324...

Страница 31: ......

Страница 32: ...P N 19746 Rev 4 04 01...

Отзывы: