tank Size

hardneSS

UnIt 

caPacItY

lBS oF Salt

11x11” Grid

15x17” Grid

18x33” Grid

18x40” Grid

24x41” Grid

24x50” Grid

24k 

0.75 cu ft 

8x44”

0 - 12 gpg

15K

4.5 lbs

Grid

NO GRID

NO GRID

NO GRID

TOO 

LARGE

TOO 

LARGE

12 - 25 gpg

20K

7.5 lbs

Grid

Grid

NO GRID

NO GRID

25+ gpg 

24K

11.25 lbs

Grid + 3” Legs

Grid

Grid

Grid

32k 

1.0 cu ft 

9x48”

0 - 12 gpg

20K

6 lbs

Grid

NO GRID

NO GRID

NO GRID

TOO 

LARGE

TOO 

LARGE

12 - 25 gpg

27K

10 lbs

Grid + 3” Legs

Grid

Grid

Grid

25+ gpg 

32K

15 lbs

Grid + 6” Legs

Grid + 3” Legs

Grid

Grid

40k 

1.25 cu ft 

10x44”

0 - 12 gpg

25K

7.5 lbs

Grid

Grid

NO GRID

NO GRID

TOO 

LARGE

TOO 

LARGE

12 - 25 gpg

34K

12.5 lbs

Grid + 3” Legs

Grid

Grid

Grid

25+ gpg 

40K

18.75 lbs

TOO SMALL

Grid + 3” Legs

Grid + 3” Legs

Grid + 3” Legs

48k 

1.5 cu ft 

10x48”

0 - 12 gpg

30K

9 lbs

Grid + 3” Legs

Grid

Grid

Grid

TOO 

LARGE

TOO 

LARGE

12 - 25 gpg

41K

15 lbs

Grid + 6” Legs

Grid + 3” Legs

Grid

Grid

25+ gpg 

48K

22.5 lbs

TOO SMALL

Grid + 6” Legs

Grid + 3” Legs

Grid + 3” Legs

64k 

2.0 cu ft 

12x52”

0 - 12 gpg

40K

12 lbs

Grid + 3” Legs

Grid

Grid

Grid

Grid + 

5” Legs

Grid + 

5” Legs

12 - 25 gpg

54K

20 lbs

TOO SMALL

Grid + 6” Legs

Grid + 3” Legs

Grid + 3” Legs

25+ gpg 

64K

30 lbs

TOO SMALL

TOO SMALL

Grid + 6” Legs

Grid + 6” Legs

5) 

 UnIt caPacItY: 

 The Unit Capacity equates to your system's rated capacity based on your tank size and 

hardness level. In the first column, identify the 

section

 containing your softener tank size and then within this 

section, find the 

row

 pertaining to your 

hardness

 level. Then look under the 

Unit capacity

 column to find the 

most efficient program value to use for your 

Unit capacity

 and record it 

in the table on page 2.

 

note that 

your Unit capacity program value may actually be lower than the tank’s maximum capacity.

 This is to 

accommodate a lower salt dose for regeneration.

6) 

 lBS oF Salt: 

 

In the first column, identify the 

section

 containing your softener tank size and then within this sec-

tion, find the 

row

 pertaining to your

 hardness

 level. Then look under the 

lbs of Salt

 column to find the most efficient 

program value to enter for your 

lbs of Salt 

per regeneration and record it 

in the table on page 2.

 

7) 

 example: 

 If you ordered a 64K grain capacity system and have 28 gpg hardness, you would look under the 64K, 2.0 

cu ft section and then look under the 25+ gpg row for your particular programming values. Note that the 11x11” and the 
15x17” brine tanks are too small for the amount of brine needed to regenerate a 64K grain capacity system with 25+ gpg 
hardness. According to the table you would opt for an 18” diameter brine tank with a grid plus 6” legs

Содержание 5600 Econominder

Страница 1: ...Fleck 5600 Metered Water Softener Install ation Guide v1 0...

Страница 2: ...nd LBS of Salt Tank size and Hardness level determines the Unit Capacity and lbs of Salt per Regeneration OUTLET INLET Job Number Model Number Mineral Tank Size Se t ting VALUE HARDNESS Grains per Gal...

Страница 3: ...k 5600 Valve into your Home Page 9 Making the Brine Tank Connection Page 10 Making the Drain Connection Preface Thank you for your purchase of a new water softener with Fleck 5600 Meter Control Valve...

Страница 4: ...re and both figures can be used interchangeably If you get a hardness level in PPM or mg L please divide this number by 17 1 to get Grains gpg Ex If your hardness is measured at 300 PPM take 300 17 1...

Страница 5: ...6 Legs 5 Unit Capacity The Unit Capacity equates to your system s rated capacity based on your tank size and hardness level In the first column identify the section containing your softener tank size...

Страница 6: ...ig u r e 6 a Fig u r e 6 B pre install ation Before assembly of your new system be sure that the following conditions have been met for the place ment of your system Level firm surface such as concret...

Страница 7: ...B 3 Installing the fleck 5600 Valve 1 Using caution not to lift the riser tube remove the filling funnel and tape While using the included silicone lubricant packet lubri cate the inner and outer o r...

Страница 8: ...nes and use a wet rag on the lines being soldered to prevent heat damage during soldering 6 Once all connections have been made place the system into bypass by either using your existing 3 valve bypas...

Страница 9: ...o take this moment to prepare and insert the brine support grid determined from pages 4 and 5 Then pull the 474 Brine Float Assembly out of the brine well as shown in Figure 9 C 4 Next fix the 474 Bri...

Страница 10: ...be evenly press on both sides of the grey ring surrounding the tube and pull out as shown in Figure 10 A i Be sure to recut the end of the tube each time you remove it to ensure a proper seal when the...

Страница 11: ...installed and programmed Please maintain your system by keeping the softener plugged in and always keep your brine tank filled with salt to at least above the water level We appreciate your business a...

Отзывы: