Fleck 5600 Econominder Скачать руководство пользователя страница 2

PAGE 2

QualityWaterForLess.com

Help: 888-426-5001

› G e n e R a l   R e F e R e n C e

Please take a moment to review this page in order to 
familiarize yourself with these four ports on the valve 
and the programming values below. It is crucial not to 
mistake the inlet port with the outlet port. Mistaking 
and reversing the inlet and outlet ports will lead to 
failure of your softener system.

As you work through this guide, please make sure to 
follow all instructions exactly. 

PdF viewers may click 

underlined text to jump to that page or the page 
number in the bottom corner of every page to 
jump to the table of contents.

 All our installation 

guides may be found on our site under “Information.”

d R a I n

B R I n e

›PRo G R a m m I n G

To the right are the setting values for your softener. 

You can 

calculate the missing values on pages 4 and 5 of this 
guide.

 There we will cover identifying the essential values of, 

hardneSS

UnIt caPacItY

, and 

lBS oF Salt

Tank size and Hardness level determines the Unit Capacity 
and lbs of Salt per Regeneration.

o u t l e t

I n l e t

Job Number:  

  

 

Model Number:  

  

 

Mineral Tank Size:  

  

s e t t I n G

Va l u e

hardneSS

       Grains per Gallon

UnIt caPacItY

        ,000 Grains

Gal caPacItY

        00 Gallons

lBS oF Salt

        lbs

F I G u R e   2 - a

F I G u R e   2 - B

The 

Gallon caPacItY

 

equates 

to the Unit Capacity 

divided

 by the Hardness

minus

 15% of the result (Example: 

64K tank / 28 gpg hardness = 2,286 gal; 2,286 gal - 343 = 
1,943 gal capacity. 

Unit capacity and hardness can be 

determined from pages 4 and 5

). If the result exceeds 

the highest number on the dial, use the next smallest  

Unit capacity value 

listed on 

the table on page 5

 in the 

equation above. To set Gallon Capacity, pull out and rotate 
the right dial and line up your Gallon Capacity value with the 
white dot (Figure 2-A).

To set 

lBS oF Salt

 per regeneration, take the 

lbs of Salt 

value

 from the 

table above/the table on page 5

, move to 

the rear of the valve, loosen the flat head screw holding the 
lbs of salt selector, line up the point of the selector with the 
lbs of salt value, and tighten the selector (Figure 2-B).

Содержание 5600 Econominder

Страница 1: ...Fleck 5600 Metered Water Softener Install ation Guide v1 0...

Страница 2: ...nd LBS of Salt Tank size and Hardness level determines the Unit Capacity and lbs of Salt per Regeneration OUTLET INLET Job Number Model Number Mineral Tank Size Se t ting VALUE HARDNESS Grains per Gal...

Страница 3: ...k 5600 Valve into your Home Page 9 Making the Brine Tank Connection Page 10 Making the Drain Connection Preface Thank you for your purchase of a new water softener with Fleck 5600 Meter Control Valve...

Страница 4: ...re and both figures can be used interchangeably If you get a hardness level in PPM or mg L please divide this number by 17 1 to get Grains gpg Ex If your hardness is measured at 300 PPM take 300 17 1...

Страница 5: ...6 Legs 5 Unit Capacity The Unit Capacity equates to your system s rated capacity based on your tank size and hardness level In the first column identify the section containing your softener tank size...

Страница 6: ...ig u r e 6 a Fig u r e 6 B pre install ation Before assembly of your new system be sure that the following conditions have been met for the place ment of your system Level firm surface such as concret...

Страница 7: ...B 3 Installing the fleck 5600 Valve 1 Using caution not to lift the riser tube remove the filling funnel and tape While using the included silicone lubricant packet lubri cate the inner and outer o r...

Страница 8: ...nes and use a wet rag on the lines being soldered to prevent heat damage during soldering 6 Once all connections have been made place the system into bypass by either using your existing 3 valve bypas...

Страница 9: ...o take this moment to prepare and insert the brine support grid determined from pages 4 and 5 Then pull the 474 Brine Float Assembly out of the brine well as shown in Figure 9 C 4 Next fix the 474 Bri...

Страница 10: ...be evenly press on both sides of the grey ring surrounding the tube and pull out as shown in Figure 10 A i Be sure to recut the end of the tube each time you remove it to ensure a proper seal when the...

Страница 11: ...installed and programmed Please maintain your system by keeping the softener plugged in and always keep your brine tank filled with salt to at least above the water level We appreciate your business a...