8. Connect the ethernet cable to the “DRIVER
BOARD 1” ethernet port behind the Touch
Panel screen.
NOTE:
WHILE “DRIVER BOARD 2” PORT IS
ALSO A VALID PORT, IT IS TEMPORARILY
PLUGGED TO AVOID CONFUSION. THE
COLOR TOUCH PANEL PROGRAM
DEFAULTS TO DRIVER BOARD 1.
9. Connect the straight end of the switch
extension to the “PORT 1” switch port
behind the Touch Panel screen. Ensure the
both the switch and ethernet cable
connections are fully engaged.
NOTE:
WHILE “PORT 2” SWITCH PORT IS
ALSO A VALID PORT, IT IS TEMPORARILY
PLUGGED TO AVOID CONFUSION. YOU
WILL ACTIVATE THE PORT YOU USE WHEN
YOU GO THROUGH THE EQUIPMENT
SETUP WIZARD PROGRAM ON YOUR
COLOR TOUCH PANEL LATER.
Draw Switch Options
When the draw spout is activated, the spigot
switch relays the signal to the Flavor Burst
®
system, telling it to activate the pumps and
syrups as product is drawn from the spout.
Flavor Burst highly recommends integrated
(internal) switches be installed to power the
CTP 80BEV system.
However, the correct
integrated switches for your freezer depend on
the freezer model as well as what product is
being used (shake vs. slush, etc). If the
installer has the correct integrated switches,
install these instead of the external switches
included with this system.
If no integrated switches are available, install
the ELE 510 external switches from your Spare
Parts Kit as directed in the next section; these
may be replaced at a later time with integrated
switches if you wish. Use the chart below to
determine which switches you need and contact
your local distributor for further information.
FREEZER MODEL - PRODUCT
SWITCH KIT
All - Universal
ELE 510
Taylor 430 – Shake / Slush
ELE 474-NCL
Taylor 428 / 432 - Slush
ELE 518
Taylor 428 / 432 - Shake
ELE 526
Connecting to the Internal Switch
1. For freezers that have an integrated switch
already built into the freezer, insert one end
of the switch extension into the integrated
switch port on the freezer. Ensure the other
end of the switch is fully inserted into
“PORT 1” of the Touch Panel.
NOTE:
WHILE “PORT 2” SWITCH PORT IS
ALSO A VALID PORT, IT IS TEMPORARILY
PLUGGED TO AVOID CONFUSION. YOU
WILL ACTIVATE THE PORT YOU USE WHEN
YOU GO THROUGH THE EQUIPMENT
SETUP WIZARD PROGRAM ON YOUR
COLOR TOUCH PANEL LATER.
Содержание CTP 80BEV
Страница 7: ...6 PAGE INTENTIONALLY LEFT BLANK...
Страница 9: ...8 General System Overview Figure 1...
Страница 14: ...13 PAGE INTENTIONALLY LEFT BLANK...
Страница 15: ...14 Blending Assembly and Related Parts Figure 3...
Страница 17: ...16 Syrup Pump and Related Parts Figure 4...
Страница 19: ...18 Sanitizer Pump and Related Parts Figure 5...
Страница 22: ...21 PAGE INTENTIONALLY LEFT BLANK...
Страница 23: ...22 Electronic Parts and Connections Figure 6...
Страница 25: ...24 Spare Parts Kit Figure 7...
Страница 26: ...25 PAGE INTENTIONALLY LEFT BLANK...
Страница 38: ...37 PAGE INTENTIONALLY LEFT BLANK...
Страница 50: ...49 PAGE INTENTIONALLY LEFT BLANK...
Страница 72: ...71 PAGE INTENTIONALLY LEFT BLANK...