background image

ABOUT YOUR NEW ROCCO ROOM HEATER

The Flavel Rocco decorative fuel effect room heater incorporates a unique and

highly developed fuel bed which gives the realism of a loose log layout combined

with realistic flames and glow. The use of durable hard ceramic material in the

construction of the fuelbed components ensures long and trouble free operation.

When first using the new fire a slight smell may be noticed. This is due to small

deposits of oil on the firebox, but will soon disappear. Please take the time to fully

read these instructions as you will then be able to obtain the most effective and

safe operation of your fire.

DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO USE THIS APPLIANCE

IF THE GLASS PANEL IS BROKEN OR HAS BEEN REMOVED.

IMPORTANT SAFETY INFORMATION

WARNING : This appliance has a hot surface and as with all heating

appliances a fireguard should be used for the protection of children, the

elderly and infirm. Fireguards should conform to B.S. 8423 : 2002

(Fireguards for use with gas heating appliances). Servicing should be

carried out annually by a competent person such as a GAS SAFE registered

engineer. It is a condition of BFM Europe Ltd. lifetime guarantees schemes

that this is carried out by a competent person i.e a GAS SAFE registered

Engineer.

The service should include visually checking the appliance, flue terminal and

fireplace for accumulation of debris around the firebox, and inspection of the

ceramic logs, replacing as necessary. Should debris be found upon the fuel-bed,

please contact a GAS SAFE registered installer. The condition of the ceramic log

set should be carefully checked and

if necessary the whole unit should be

replaced with a genuine replacement set.

After any servicing work a gas tightness check must always be carried out.

Any debris or deposits should be removed from the log set from time to time. This

may be carried out by referring to the cleaning section as described later in this

book. Only the fuelbed components as supplied must be used and complete and

genuine replacements must be used. Always keep furniture and combustible

materials well clear of the fire and never dry clothing or items either on or near to

the fire. Never use aerosols or flammable cleaning products near to the fire when

it is in use.

SPILLAGE MONITORING SYSTEM

This appliance is fitted with a spillage monitoring system which shuts down the fire

if the evacuation of combustion products from the fire is affected by a partially or

fully blocked flue pipe. If this system operates the fire will go out. If this occurs,

leave the fire for at least three minutes then follow the lighting procedure as

described in the previous section.

3

Содержание Rocco FCFL**RN3

Страница 1: ...M HEATER User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No FCFL RN3 is for use on Natural Gas G20 at a supply pr...

Страница 2: ...the top of the appliance and the depth of the shelf does not exceed 150mm The fire may be installed below combustible shelves which exceed 150mm deep providing that the clearance above the fire is in...

Страница 3: ...i e a GAS SAFE registered Engineer The service should include visually checking the appliance flue terminal and fireplace for accumulation of debris around the firebox and inspection of the ceramic l...

Страница 4: ...from the pipe Once gas is available at the pilot by turning the control knob further anticlockwise the piezo igniter will cause a spark at the pilot to light the pilot burner Once the pilot burner is...

Страница 5: ...e main burner off at this point a clicking noise will be heard from the motor Fig 2 If the remote does not work first check the LED in the top left hand corner is illuminating when the button is press...

Страница 6: ...er than at annual service intervals If carbon or soot accumulates on the logs this should be removed by carefully brushing the fuelbed using a soft brush For instructions on how to remove the glass pa...

Страница 7: ...ions below for removal and re fitting The glass panel should be cleaned gently with a soft damp cloth and glass cleaner DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO CLEAN THE GLASS PANEL WHEN THE APPLIAN...

Страница 8: ...Fig 5 leaving the rear section as shown to allow the fitiing of Log A Fig 5 b Place the largest Log A centrally onto the fuel bed support behind the burner flame strip Ensure that the fuel bed Log A...

Страница 9: ...bed base log A as shown below in Fig 7 using the groove in Log A as a guide for placement Fig 7 d Fit Log C into position on left hand side of the fuel bed base log A as shown below in Fig 8 using th...

Страница 10: ...base log A as shown below in Fig 9 using the groove in Log A as a guide for placement Fig 9 e Fit Log E into position at centre of the fuel bed base log A as shown below in Fig 10 using the groove in...

Страница 11: ...hown below in Fig 12 using the raised section in the base log as a guide for position Fig 12 IMPORTANT NOTE HAVING FITTED THE GRAVEL MATERIAL IN THE BASE OF THE COMBUSTION CHAMBER ENSURE THAT NONE OF...

Страница 12: ...C F articles is kept to a minimum during installation servicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and after workin...

Страница 13: ...e top of the combustion chamber lid as shown below in Fig 13 14 Fig 13 Fig 14 13 IMPORTANT NOTE The trim assembly of this product is a working surface and as such will become hot in use Allow the prod...

Страница 14: ...specialist spares stockists whose details can be found on our web site www bfm europe com in the stockist section Log Set B 109780 REPLACING THE BATTERIES IN THE HANDSET a Remove the old 9V battery b...

Отзывы: