d)
Remove the valve retaining screws as shown below in Fig. 15
Fig. 15
d)
Remove the thermocouple, which is a push fit into the rear of the control
valve.
e)
Re-assemble in reverse order and carry out a gas tightness test.
4.4
REMOVING THE ODS- PILOT ASSEMBLY
Note : Because this appliance is fitted with an atmosphere sensing ODS-pilot
it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
a)
Remove the pilot retaining screws as described in section 4.2 d) &
fig. 14
b)
Disconnect the pipe pipe and push fit ignition lead
c)
Replacement new ODS in reverse order.
PARTS SHORTLIST
Replacement of any parts must be carried out by a competent person such as a CORGI registered gas
installer. The part numbers of the replaceable parts are as follows, these are available from specialist
spares stockists whose details can be found on our web site,www.bfm-europe.com, in the ‘stockist’ sec-
tion.
Coal set
FC-P085332
ODS Pilot
B-48360
Fuelbed
B-123570
Gas valve
B-63250
Rear Fibre board
B-65320
Glass Assy (Front)FC-A085705
19
2 off valve
retaining screws
Note : Prior to replacing the oxypilot on this product due to suspected
failure of the component, please remove all debris that has collected on
the lint guard of the oxypilot itself.