Supplied By www.heating spares.co Tel. 0161 620 6677
3
SECTION 1
INFORMATION AND REQUIREMENTS
1.0 APPLIANCE INFORMATION
Main injector (1 off)
Stereomatic Injector Elbow Size 62
Pilot Type
Copreci 21100/141
Max. Gross Heat Input:
4.7 kW
Min. Gross Heat Input:
2.5 kW
Gas Rate:
0.44 m
3
/hr
Cold Pressure:
20.0+/-1.0 mbar
(8.0 +/- 0.4 in w.g.)
Ignition
Push-button Piezo
Electrode Spark Gap
4.0mm
Weight (without fender)
16.0kg
Fire box dimensions (without trim)
Width
470mm
Height
583mm
Overall Depth
165mm
Trim dimensions
Overall width
483mm
Overall height
620mm
Overall depth
32mm
Spacer dimensions
Overall width
530mm
Overall height
643mm
Overall depth
83mm
Inset Depth
Flush fit (from mounting face to rear)
128mm Minimum
3” Black Spacer (from mounting face to rear) 27mm
Gas Connection
8mm Compression fitting (supplied with fire)