background image

9

Flashtube Replacement

Turn off the power and remove the power cord before replacing the flash tube. Note the ground 
wire wrapped on the flashtube. Wear gloves to loosen the metal wire on the tube. Keep a firm 
hold on the two contact prongs of the flash tube and pull out the tube gently. Remove the contact 
prong sleeves from the old tube and put them on the new one. Hold two prongs of the new tube, 
and carefully directly towards the two copper socket outlets on the body, then push them carefully 
and firmly into place. Replace the ground wire on the flash tube as on the original tube.

TECHNICAL DATA

Flashpoint Model

Studio 300 Monolight

Studio 400 Monolight

Max Power (Ws)

300Ws

400Ws

Guide Number( ISO 100)

190ft / 58m

213ft / 65m

Color Temperature

5600±200k

Operating Voltage

AC200-240V/50Hz or AC100-120V/60Hz

Power Output Control

From 1/16 (6.0) to 1/1 (10.0) full power in tenths of a stop increments

Modeling Lamp (W)

150W

Modeling Lamp Level

5%~100%

Recycle Time

0.4~2.5s

0.4~2s

Triggering Methods

R2 Wireless built-in, Sync cord, Test button, Optical slave triggering,  
R1 Wireless USB port

Flash Duration

1/2000~1/800s

Fuse

5A

Dimension

Flash diameter Φ 5.0in/12.7cm. 
8.1in/20.6cm 
Length 13.4in/34cm

Flash diameter Φ 5.0in/12.7cm. 
9.1in/23.2cm  
Length 15in/38cm

Net Weight

Approx. 4.1lb / 1.9kg

Approx. 4.6 lb / 2.1 kg

Groups 

16 [A-F and 0-9]

Channels

32

R2 2.4GHz Radio Range

328ft/100m

Содержание Studio 300 Monolight

Страница 1: ...Studio 300 400 Monolight with Built in R2 2 4GHz Radio Remote System FPLFS300B FPLFS400B...

Страница 2: ...io based world of photography The Studio300 R2 and Studio400 R2 have a max recycle times of 2 5 and 2 seconds respectively and reliability that only AC can guarantee Please feel free to contact us at...

Страница 3: ...other accident send the defective back to the authorized service center for inspection and maintenance Keep dry Do not handle with wet hands immerse in water or expose to rain Failure to observe this...

Страница 4: ...7 Group Channel Selection Button 8 BUZZ Audio Signal Button 9 R1 Wireless Control Port 10 LCD Display 11 Optical Slave Light Sensor 12 Modeling Lamp Indicator 13 Power Ready Indicator 14 Select Dial S...

Страница 5: ...ROP mode 11 Modeling Lamp shows the power in percentage 12 Modeling Lamp is OFF when the flash is triggered ON upon recycle LCD Panel 1 Power Cord 2 Lamp Cover 3 Modeling Lamp 4 Instruction Manual Sep...

Страница 6: ...tion Firmly insert the power cord and connect the flash to an AC power source Turn on the power switch 3 Modeling Lamp Short press the Modeling Lamp Button 5 to choose the modeling lamp s mode OFF ON...

Страница 7: ...the group indicator on the LCD panel is blinking turn the select dial to change A long press on the GR CH button adjusts the wireless channel When the channel indicator on the LCD panel is blinking t...

Страница 8: ...l Memory Function The device is equipped with a memory function for retaining all the settings 3 seconds after you set it When turning on the flash the next time the panel setting will be set the same...

Страница 9: ...be TECHNICAL DATA Flashpoint Model Studio 300 Monolight Studio 400 Monolight Max Power Ws 300Ws 400Ws Guide Number ISO 100 190ft 58m 213ft 65m Color Temperature 5600 200k Operating Voltage AC200 240V...

Страница 10: ...the warranty If the product had failures or was exposed to moisture do not use it until it is repaired by profes sional Disconnect the power when cleaning the flash or when changing the flashtube mode...

Страница 11: ...30 days whichever is longer or for any additional period of time that may be applicable in your jurisdiction If the product has been discontinued the warranty provider reserves the right to replace it...

Страница 12: ......