Finder User Guide | www.flashforge.com
56
extruder/build plate.
e. Make Current Position Zero button: Set the current position of the
extruder/build plate as (0, 0, 0). (NOTE: X, Y, and Z boxes are for display purposes.
Changing the value in the boxes will not affect anything.
f. Center X/Y/Z button: Extruder and build platform will back to the zero (0, 0, 0)
you set last time.
g. X/Y Speed and Z Speed: Set the move speed of extruder/ build platform.
● Limit Switch: In order to protect your Finder, three limit switches are equipped to
control the maximum position, and the three limit switches corresponding to X/Y/Z
axis limit switch. It has two status:
a. Not Triggered: If the extruder/build plate don’t move to its maximum, X/Y/Z axis
limit switch is not triggered, and shows “Not Triggered”.
b. Triggered: If the extruder/build plate moves to its maximum, X/Y/Z axis limit
switch is triggered, and shows “Triggered”.
● Stepper Motor Controls: Allows users to control to stepper motor. Click
[Enable]
,
and lock the motor so it does not allow any movement; click
[Disable]
, and unlock the
motor to be controlled manually.
● LED Color: Allows users to change the LED color of Finder.
● Extruder Controls: You can set the value of “
Motor Speed(RPM)
”, which can
control the rotation speed of filament feeding wheel. The motor rotation time can be
controlled via setting the value of “
Extruder Duration
”.Generally we suggest the
users choose option of continuous time 60 seconds. The filament must loaded in the
extruder before motor starts.
Therefore, do not start rotation operation until the
extruder temperature reaches to the printing temperature of filament.
For PLA
filament, the extruder temperature should reach 200
℃
, after reaching the extruder
temperature, click the
[Forward]/[Reverse]
rotation button to control filament load