background image

Manual external FLARM™ / PowerFLARM™  Display V3+Mm 

External FLARM™/ PowrFLARM™ 

Display V3+Mm        

with Software-version 3.7

 

 

 

 

 

  

 

Page 

17

 

 
Maintenance 
 

The V3+ display itself is maintenance-free, however it is recommended to perform the following checks, if 
problems are suspected and/or general maintenance check-ups are planned: 

 

o

 

Do all LED’s illuminate during the start-up test? 

o

 

Does the Mode button function correctly; dirt/dust particles can obstruct its function? 

o

 

Is the buzzer opening (display lower edge) free from dirt or adhesive residues? 

o

 

Are all 4 levels by volume adjustment (short push, < 0.8 s) audible? 

 

Do not forget the FLARM

TM

 mainframe during the same check-up: 

 

o

 

Is the software & fixed-obstacle database up-to-date? 

o

 

Are the antennas undamaged and properly installed? 

o

 

Are the cables/plugs undamaged and properly installed? 

 

Software Update 
 

The V3+M display is equipped with a boot-loader – this allows updating of integrated display software. 
 
Should FLARM

TM

 make changes/additions on current data communication or adjustments to the 

operating/indication of different warning levels, the display software can be updated. 
 
Only in exceptional cases is the update of the display consequent to a FLARM

TM

 update mandatory. As a 

rule FLARM

TM

 updates are compatible with current peripheral devices – but can include new functions and 

operations. 
 
Further information regarding updates is located on: 

http://www.flarm.com/support/updates/

 

Updated display software is found on our web-site:   

www.swiss-bat.ch

Included on website are steps for software updates for the display. 
 
 

Technical data 
 

Dimensions: 

25 * 63 * 5.6 mm excl. RJ12-jack 
(Jack additional app. 10 mm backwards) 

 

Weight: 

11.6 g (display without cable and adapter) 

Supply voltage: 

VCC DC directly from FLARM, 

Power consumption:  average consumption 12 mA by 12V (144 mW) 
Protection class: 

IP52 

Attachment: 

Panel attachment (adhesion or screw) 

Temperature range: 

-20°C…60°C 

Humidity: 

10-90%, no condensation 

Vibrations: 

For applications in strong vibrating conditions e.g. helicopter,

 

Powered aircraft.

 

Manufacturing 
country: 

 
Switzerland 

 
Further technical information, tips and problem solving are located on our homepage 

www.swiss-bat.ch

 

 

 

Содержание FLARM V3+Mm

Страница 1: ...Manual external FLARMTM Display V3 Mm Fly with far sightedness www swiss bat ch External FLARMTM PowerFLARM Display V3 Mm for Powered aircraft Manual V3 Mm Software Version 3 7 22th May 2015 a ...

Страница 2: ...nce of another moving aircraft if the aircraft is equipped either with FLARM compatible systems ADS B OUT 1090ES on 1090MHz or an interrogated transponder Mode C or S As FLARMTM main device neither interrogates nor operates as a transponder the displayV3 as well cannot be detected by TCAS or air traffic control Warranty The period of the warranty ceases immediately in all of the following cases th...

Страница 3: ... display Wiring to FLARMTM Wiring to PowerFLARMTM PORTABLE Wiring to PowerFLARMTM CORE Two seater version Other variations Configuration Start up Status indicators Mode Button Operation modes Nearest Mode Warning Mode Traffic Functions Airplane warning Forecasting Traffic Transponder object indication Fixed obstacles warning Indicator Mute mode Maintenance Software updates Technical data Frequentl...

Страница 4: ...Status LED s 4 status LED s green situated vertically indicate operating status of FLARMTM Direction and height indicators 12 circular placed LED s for the direction and 4 LED s for the traffic height indication The indication appears as relative direction indication which means from the point of pilot flight direction and detects an approaching threat rapidly Using the 2 colour display the object...

Страница 5: ...e of the display for an acoustic warning In the case of an approaching threat the acoustic alarm sounds in addition to the red indicator The volume can be adjusted into 4 levels The signal can be muted for a 5 minute period in order to consciously eliminate acoustic noise while thermal circling with other glider aircraft For more detailed instructions refer to the chapter Operation ...

Страница 6: ...ment For installation of the display an adhesive attachment proves to be the most practical method For this purpose two pre cut double sided mounting adhesives are included For clean smooth surfaces the thinner adhesive should be used for rougher surfaces the foam adhesive is the preferred choice Attention in order to guarantee optimal adhesion the surface must be absolutely clean and free from oi...

Страница 7: ...ruments have a non stabilized battery supply available on their interface This enables the peripheral device s power supply through simple wiring Non stabilized means the FLARM device supply is connected without voltage control and without internal fuse protection to the interface Strictly adhere to the manufacturer s references regarding the connection and fuse protection of the mainframe The dis...

Страница 8: ...werFLARMTM The CORE has another independent data interface at the DSUB 9 jack this allows a possible connection to the display Two seater version Using the Y adapter RJ12 6 pole two external displays can be operated on FLARMTM or PowerFLARMTM In order to avoid data collisions while operating both displays one of the displays must be configured as PAX refer to operation manual All FLARM and display...

Страница 9: ...han 3 s or FLARM including the display must be restarted cut power supply and power up again Parameter No 1 2 3 4 5 6 Parameter brightness indicator parallel operation FLARMTM mainframe interface unit of measurement compatibility mode Status LED RX TX GPS Power RX TX TX GPS Value 1 15 strongly dimmed display PIC LED on signal on 4800 Baud KM indication OFF direction 1 LED Value 2 45 dimmed display...

Страница 10: ...hind the display has its own built in signal hence the signal of the FLARMTM can then be switched off Parameter 4 Interface Transmission Rate o Values 1 6 according to the table The extension interface of FLARMTM operates normally with 4800 Baud If the display is operated on data interface alignment of the baud rate of the display is possible As no high quality cables with protective shielding are...

Страница 11: ...s in groups 5 On the distance indicator a control symbol appears briefly for the adjusted measuring unit The distance depends on the adjusted configuration and is indicated in KM or NM afterwards the measuring unit is no longer visible Please ensure The distance indicator is given in KM There is no conversion of the given value symbol refers to European metric system The distance indicator is give...

Страница 12: ... constantly during operation The Power LED blinks when voltage is below 8 VDC as FLARM will not function with low voltage Communication failure If data communication is interrupted with the mainframe no data received for more than 3 seconds the status LED s will show as follows Power LED is constantly on RX TX and GPS LED s all flash together Check wiring to mainframe Is FLARM mainframe in operati...

Страница 13: ...Mode The selection of this mode is shown after a button press 2 s with a downwards symbol indicated on the display Warning Mode In Warning Mode the signal occurs only after an evaluation confirms an approaching threat Warnings are always shown with red flashing and are accompanied by an acoustic signal Depending on the threat 3 threat levels the flashing and buzzing frequencies will change The sel...

Страница 14: ...hreat less than approximately 14 18 s until possible collision red LED buzzer interval middle 4 Hz Immediate threat less than approximately 6 8 s until possible collision red LED buzzer interval rapid 6 Hz Indicator examples V3 Display Mode FLARM Compatibility Mode Moderate threat from approximately 3 o clock flashing buzzing slow 2 Hz Severe threat from approximately 1 o clock flashing buzzing mi...

Страница 15: ... Indication The new FLARMTM devices or compatible external receivers e g TRX 1090 from GARRECHT are additionally capable of receiving and evaluating signals from transponders Signals from a transponder featuring ADS B OUT include the GPS coordinates of the sending aircraft therefore FLARMTM can evaluate the received signals calculate and recognize a possible collision threat The indication on the ...

Страница 16: ...rn as follows simultaneous flashing of two LED s flashing and buzzing rate depends on threat same as Aircraft Warning Comment A fixed obstacle is always in the moving direction there is no specific direction indication There is no vertical position indication There is a warning given when the aircraft flies underneath power transmission lines and cable car wiring The indicator updates every second...

Страница 17: ...ns on current data communication or adjustments to the operating indication of different warning levels the display software can be updated Only in exceptional cases is the update of the display consequent to a FLARMTM update mandatory As a rule FLARMTM updates are compatible with current peripheral devices but can include new functions and operations Further information regarding updates is locat...

Страница 18: ...ays set on loud This function operates intentionally for safety reasons at the beginning of each flight day FLARMTM must be adequately audible The buzzer can be intentionally adjusted afterwards to a lower volume level or even disabled completely After a change over from older V2 display to the new V3 M display the display is not illuminated The first display generation the V2 operates with a 3 3V...

Страница 19: ...Manual external FLARM PowerFLARM Display V3 Mm External FLARM PowrFLARM Display V3 Mm with Software version 3 7 Page 19 Notes ...

Страница 20: ......

Отзывы: