Page 37
Chapter 10. Verifying the Installation
Verifying the proper installation of the cabinet is done in two parts:
1. Verifying the physical installation
2. Verifying the BaseStation operation
All items listed must be verified before the installation can be considered complete.
10.1. Verifying the Physical Installation
Verify the following:
1. Clearance requirements are met — at least 24” front and 6” rear. There must be room to
open the cabinet doors for service.
2. The base station is powered up. All the LEDs in
Table 8.1 Power On Expected LEDs
must
reflect the states listed in the table. The system should remain in the powered up state. If it
is necessary to power down the base station, do so
only
in accordance with the instructions
in
Chapter 9. Powering Down the Cabinet
.
3. Correct terminations on all T1 and alarm cables
4. No crimps in RF cables
5. RF cable markings match those specified in
Chapter 6. Connecting the Antennas Cables
.
10.2. Verifying the Base Station Operation
Operation of the base station is verified by logging in and confirming communication with the
network. This verifies both the base station operation and the connectivity of the T1/Ethernet link.
Procedure 10-1 Communicating with the Core Network
1.
Connect a PC to the serial port of the MCU.
2.
Run a terminal emulator such as Microsoft Window HyperTerminal.
3.
At the
Login:
prompt, type
install
and press
Enter
.
4.
At the
Password:
prompt, type the install login password and press
Enter
.
5.
You should see status messages ending in the message
The system is Up at the required run level — 4
. Press
Enter
.
6.
The system should respond with the
BS_Name#>
prompt. This confirms that the base
station is at least minimally operational.
RadioRouter
®
BaseStation Installation Guide — Draft
Version 0.5 - © 2003
Page 37
Содержание RadioRouter
Страница 2: ...Intentionally blank page RadioRouter BaseStation Installation Guide Draft Version 0 5 2003...
Страница 10: ...Page 8 Intentionally blank page RadioRouter BaseStation Installation Guide Draft Version 0 5 2003 Page 8...
Страница 50: ...Page A 2 Alarm sensor cables RadioRouter BaseStation Installation Guide Draft Version 0 5 2003 Page A 2...