VENT AND FIREPLACE SIZE
*Flare-RD-45 is shipped with 5x8 vent. All other Flare 45 are shipped with the 4x6 vent
MINIMUM COMBUSTIBLE CLEARANCES FROM VENT
•
HORIZONTAL VENT CLEARANCES:
A minimum clearance of
3 inches
(76mm) to the top and
1 inches
(51mm) to the sides
and bottom of the vent pipe on all horizontal runs to combustibles is required.
•
VERTICAL VENT CLEARANCES:
A minimum of
1 inches
(25mm) all around the vent pipe on all vertical runs to combustibles
is required except for clearances in appliance enclosures.
•
Horizontal vents
have a minimum
1/4 inch
(6mm)
rise per 1 foot
towards the termination.
Frame cutout table taken from the DuraVent or ICC installation manual
Size
Vent Size
Flare 30
4x6
Flare 45*
5x8 or 4x6 *
Flare 50
5x8
Flare 60
5x8
Flare 70
5x8
Flare 80
5x8
Flare 100
5x8