Remote Control Commands
Remote control commands may be issued to the SD5902 singly, or combined in a string with other
commands. The string may optionally be terminated with an ASCII linefeed character (hex 0A, decimal
10), and commands may optionally be separated by the semicolon character ‘;’. The SD5902 is not case
sensitive so combinations of upper and lower case are acceptable.
Command descriptions
Command: A1
Function:
Move Switch ‘A’ to Position 1
Response:
GPIB: Data Message in format a,b as shown below, if no other query command is
present in the command string. USB: None
Front Panel:
Button 1 in the ‘Instrument A’ group
Command: A2
Function:
Move Switch ‘A’ to Position 2
Response:
GPIB: Data Message in format a,b as shown below, if no other query command is
present in the command string. USB: None
Front Panel:
Button 2 in the ‘Instrument A’ group
Command: A3
Function:
Move Switch ‘A’ to Position 3
Response:
GPIB: Data Message in format a,b as shown below, if no other query command is
present in the command string. USB: None
Front Panel:
Button 3 in the ‘Instrument A’ group
Command: A4
Function:
Move Switch ‘A’ to Position 4
Response:
GPIB: Data Message in format a,b as shown below, if no other query command is
present in the command string. USB: None
Front Panel:
Button 4 in the ‘Instrument A’ group
Command: A?
Function:
Return Switch ‘A’ Position
Response:
GPIB and USB: A single digit ‘1’, ‘2’, ‘3’, ‘4’ indicating the position, or ‘0’ if the
switch is not present or is in an error condition
Front Panel:
None
Command: B1
Function:
Move Switch ‘B’ to Position 1
Response:
GPIB: Data Message in format a,b as shown below, if no other query command is
present in the command string. USB: None
Front Panel:
Button 1 in the ‘Instrument B’ group
Command: B2
Function:
Move Switch ‘B’ to Position 2
Response:
GPIB: Data Message in format a,b as shown below, if no other query command is
present in the command string. USB: None
Front Panel:
Button 2 in the ‘Instrument B’ group
Command: B3
Function:
Move Switch ‘B’ to Position 3
Response:
GPIB: Data Message in format a,b as shown below, if no other query command is
present in the command string. USB: None
Front Panel:
Button 3 in the ‘Instrument B’ group