background image

           

 

 

 

 

 

 

   

 

TABLE

ROUTINE 

MAINTENANCE 

PROCEDURES 

        1

           

 

 

 

 

 

 

 

  

FIGURES

TWO STAGE CONTRA-ROTATING INSTALLATION  

 

 

 

 

 

         1

FIXING ARRANGEMENT OF TERMINAL BLOCK

(DRAWING 

NO: 

D258302 

F) 

 

         2

WIRING DETAIL - SINGLE PHASE FANS WITH DUCT MOUNTED TERMINAL BOX    

 

3

 

        

WIRING DETAIL - SINGLE PHASE FANS USING TERMINAL BOX ON MOTOR  

 

 

4

           

WIRING DETAIL - SINGLE-PHASE DIRECT-DRIVE MOTOR WITH SPEED CONTROLLER    

5

           

WIRING DETAIL - SINGLE PHASE WEG MOTORS 

 

 

 

 

 

 

6

WIRING DETAIL - THREE PHASE FANS WITH DUCT MOUNTED TERMINAL BOX   

 

7

WIRING DETAIL - THREE PHASE FANS USING TERMINAL BOX ON MOTOR  

 

 

8

WIRING DETAIL - THREE-PHASE MOTOR WITH ISOLATOR FITTED   

 

 

 

9

WIRING DETAIL - THREE-PHASE DIRECT-DRIVE MOTOR WITH TRANSFORMER TYPE SPEED 

CONTROLLER 

            10

WIRING DETAIL - THREE-PHASE DIRECT-DRIVE MOTOR WITH ELECTRONIC TYPE SPEED 

CONTROLLER 

            11

WIRING DETAIL (THREE-PHASE DIRECT-DRIVE MOTOR WITH CHANGEOVER SWITCH)   

12

DRAWING OF TORQUE SETTINGS FOR FIXINGS

(DRAWING 

NO: 

D248284 

K) 

          13

Содержание AEROFOIL AXIAL FAN

Страница 1: ...AEROFOIL AXIAL FLOW FANS SAFETY INSTALLATION AND MAINTENANCE INSTRUCTIONS PART NO 416421 AIR MOVEMENT FIRE SAFETY...

Страница 2: ...OTECTION 5 2 BEARING TEMPERATURE VIBRATION LEVEL MONITORING SENSORS 5 3 ANTI CONDENSATION HEATER 5 4 EMERGENCY USE FANS 5 5 FANS WITH HAZARDOUS AREA MOTORS 5 6 SWITCH ON 5 7 MAINTENANCE 6 FIXINGS 6 1...

Страница 3: ...TROLLER 5 WIRING DETAIL SINGLE PHASE WEG MOTORS 6 WIRING DETAIL THREE PHASE FANS WITH DUCT MOUNTED TERMINAL BOX 7 WIRING DETAIL THREE PHASE FANS USING TERMINAL BOX ON MOTOR 8 WIRING DETAIL THREE PHASE...

Страница 4: ...entative together with full fan motor nameplate details Should a fan failure occur whilst the product is under warranty the Fl kt Woods service centre in Colchester should be contacted before any repa...

Страница 5: ...fan nameplate For two stage contra rotating fans see Figure 1 Sharp bends in the ductwork close to the fan must be avoided Adequate room must be allowed round the fan for inspection and maintenance Th...

Страница 6: ...ils of the wiring to the terminals of smaller fans Figure 2 shows the correct assembly sequence of terminal box parts and the torque to be applied It is essential that no lockwashers or nuts are place...

Страница 7: ...ontactor is manually reset 5 3 BEARING TEMPERATURE AND VIBRATION MONITORING SENSORS Monitoring sensors if fitted in the fan system should be wired to automatically switch off the fan if a fault occurs...

Страница 8: ...he motor or its wiring 6 MAINTENANCE ATTENTION No maintenance work should be attempted before switching off and completely isolating the fan assembly its anti condensation heater If fitted and its con...

Страница 9: ...should be measured at 500V d c each month If the reading is less than ten megohms the motor should be dried in a warm airflow typically 40 C and re checked before running the motor The fan should be o...

Страница 10: ...s than ten meghoms a break down in the motor winding insulation could be the reason and a motor rewind overhaul may be necessary Ensure that there is no smell of burnt insulation in the vicinity of th...

Страница 11: ...here no relevant harmonized standards exists Woods fans are driven by AC induction motors which are inherently compliant if supplied with a truly sinusoidal AC supply Where the fan motor is supplied v...

Страница 12: ...retaining plate Replace the 130mm Duramid seal if it is damaged 9 Examine the clearance between the fan impeller blade tips and the fan duct Check the angle and the security of the impeller blades Ens...

Страница 13: ...pply to Series 33 Bifurcated JM fans 10 FIGURE 1 FIGURE 2 A STANDARD TWO STAGE CONTRA ROTATING AXIAL FAN COMPRISES A FORM A RIGHT HAND FAN FOLLOWED BY A FORM B LEFT HAND FAN This does not apply to ide...

Страница 14: ...D1705 CD1706 CONTROLLER CONTROLLER CONTROLLER CONTROLLER FAN FAN FAN FAN CD1709 CD1708 PN 502271 PN 502260 PN 502273 PN 502261 1 PHASE 1 PHASE 1 PHASE 1 PHASE SPEED CONTROL WARNING SPEED CONTROL WARNI...

Страница 15: ...SE WEG MOTORS CD2426 FAN CD1653 CD1654 CD1656 CD1655 CONTROLLER CONTROLLER CONTROLLER CONTROLLER 1 PHASE 1 PHASE 1 PHASE 1 PHASE FAN FAN FAN WIRING DETAIL SINGLE PHASE DIRECT DRIVE MOTOR WITH SPEED CO...

Страница 16: ...W1 W2 U2 V2 U1 V1 W1 W2 U2 V2 U1 V1 W1 W2 U2 V2 U1 V1 W1 W2 U2 V2 U1 V1 W1 W2 U2 V2 U1 V1 W1 PN 83771 PN 83772 CD 1344 1 PN 407941 CD 1559 WIRING DETAIL THREE PHASE FANS WITH DUCT MOUNTED TERMINAL BO...

Страница 17: ...PHASE 3 PHASE 3 PHASE CD1683 PN 502333 PN 502334 WIRING DETAIL THREE PHASE FANS USING TERMINAL BOX ON MOTOR CD1546 CD1547 CD1550 CD1545 WIRING DETAIL THREE PHASE MOTOR WITH ISOLATOR FITTED 14 U1 V1 W1...

Страница 18: ...57 U1 V1 W1 V2 U2 W2 3 PHASE 3 PHASE WIRING DETAIL THREE PHASE DIRECT DRIVE MOTOR WITH ELECTRONIC TYPE SPEED CONTROLLER U1 V1 W1 V2 U2 W2 3 PHASE 3 PHASE CD1659 CD1660 U1 V1 W1 V2 U2 W2 3 PHASE CD1660...

Страница 19: ...DRAWING OF TORQUE SETTINGS FOR FIXINGS FIGURE 13 16...

Страница 20: ...fety With market presence in 65 countries we are in a unique position to be a local supplier and an international partner in our customer s projects Our product brands such as SEMCO eQ eQ Prime JM Aer...

Отзывы: