background image

EC DECLARATION OF CONFORMITY

Herewith we declare that the air movement equipment designated below, on the basis of its design and
construction, in the form brought on to the market by us, is in accordance with the relevant safety and
health  requirements  of  the  EC  Council  Directives  on  Machinery,  Electromagnetic  Compatibility.  If
alterations  are  made  to  the  machinery  without  prior  consultations  with  us,  this  declaration  becomes
invalid. We further declare that the equipment identified below may be intended to be assembled with
other  equipment/machines  to  constitute  machinery,  which  shall  not  be  put  into  service  until  the
assembled  machinery  has  been  declared  in  conformity  with  the  provisions  of  these  EC  Council
Directives.

Designation of equipment:

Series/type:

Fläkt Woods Limited
Order/Stroke No:

Relevant EC Council Directives:

Machinery Directive (2006/42/EC).
Electromagnetic Compatibility Directive (2004/108/EC) where applicable (3)

Applied harmonized standards
in particular:

EN ISO 12100:2010, EN 60204-1:2006, EN ISO 12499:2008
EN ISO 5801:2008, EN ISO 13350:2008, EN 61000-6-2:2005, EN 61000-6-1:2007
EN 61000-6-3:2007/A1:2011/AC:2012, EN 61000-6-4:2007/A1:2011

Applied national standards
and technical specifications
in particular:

BS 848-2-1:2004 (BS ISO 13347-1:2004)
BS 848-6:2003 (BS ISO 14695:2003)
BS 848-7:2003 (ISO 14694:2003)

Basis of self attestation:

Quality Assurance to BS EN ISO 9001:2008
BSI Reg Firm Cert No. FM 155.

Signature of Manufacturer:

Position of signatory:

Managing Director

Date:

Notes:
For the complete list of applied standards and technical specifications see Fläkt Woods documentation.
Where no relevant harmonized standards exists.
Woods fans are driven by AC induction motors which are inherently compliant if supplied with a truly sinusoidal AC
supply. Where the fan motor is supplied via an inverter or other electronic control, verification of its compatibility
together with cabling should be sought from the control supplier.

Fläkt Woods Limited

Axial Way
Colchester CO4 5ZD
United Kingdom
Tel: +44 (0) 1206 222555
Facsimile: +44 (0) 1206 222777
Email: [email protected]
Website: www.flaktwoods.com

Registered in London No. 233771
Registered office Axial Way, Colchester, CO4 5ZD, UK

© Fläkt Woods Limited December 2009

1)

2)

3)

1)

2)

Direct Drive Axial Flow Fan

HT090JM/25/04-08/06/22 50Hz 3 S D132 40012

SO-0000716/1

04/02/2015

Ian Morehouse

Place: Colchester

Technical File Compiled By:

Iain Kinghorn
Axial Way, Colchester, CO4 5ZD, UK

10. EUROPEAN MACHINERY DIRECTIVE 2006/42/EC

1.7.4.2 CONTENTS OF THE INSTRUCTIONS

CLAUSE C)

 

Please see a typical example of an EC declaration of conformity certificate (below), which shows particulars of 

the machinery offered.

CLAUSES G) AND H) 

Fans should not be operated above maximum speed indicated, or run where the fan is operating in a stalled 

condition. Fans should also not be run in reverse unless specific advice is sought from Fläkt Woods.

CLAUSES I) AND J)

Fans should be isolated from support structures by means of anti-vibration mounts and from adjacent ductwork 

by flexible connections.

CLAUSE K)

Care should be taken when installing fans to ensure that the product orientation is correct in relation to 

direction arrows which indicate direction of air movement and impeller rotation direction. Where two-stage fans 

are shipped as two separate fan units, please refer to the appropriate two-stage assembly drawing, which is 

available on request. Also see figure 1.

8

Содержание AEROFOIL AXIAL FAN

Страница 1: ...AEROFOIL AXIAL FLOW FANS SAFETY INSTALLATION AND MAINTENANCE INSTRUCTIONS PART NO 416421 AIR MOVEMENT FIRE SAFETY...

Страница 2: ...OTECTION 5 2 BEARING TEMPERATURE VIBRATION LEVEL MONITORING SENSORS 5 3 ANTI CONDENSATION HEATER 5 4 EMERGENCY USE FANS 5 5 FANS WITH HAZARDOUS AREA MOTORS 5 6 SWITCH ON 5 7 MAINTENANCE 6 FIXINGS 6 1...

Страница 3: ...TROLLER 5 WIRING DETAIL SINGLE PHASE WEG MOTORS 6 WIRING DETAIL THREE PHASE FANS WITH DUCT MOUNTED TERMINAL BOX 7 WIRING DETAIL THREE PHASE FANS USING TERMINAL BOX ON MOTOR 8 WIRING DETAIL THREE PHASE...

Страница 4: ...entative together with full fan motor nameplate details Should a fan failure occur whilst the product is under warranty the Fl kt Woods service centre in Colchester should be contacted before any repa...

Страница 5: ...fan nameplate For two stage contra rotating fans see Figure 1 Sharp bends in the ductwork close to the fan must be avoided Adequate room must be allowed round the fan for inspection and maintenance Th...

Страница 6: ...ils of the wiring to the terminals of smaller fans Figure 2 shows the correct assembly sequence of terminal box parts and the torque to be applied It is essential that no lockwashers or nuts are place...

Страница 7: ...ontactor is manually reset 5 3 BEARING TEMPERATURE AND VIBRATION MONITORING SENSORS Monitoring sensors if fitted in the fan system should be wired to automatically switch off the fan if a fault occurs...

Страница 8: ...he motor or its wiring 6 MAINTENANCE ATTENTION No maintenance work should be attempted before switching off and completely isolating the fan assembly its anti condensation heater If fitted and its con...

Страница 9: ...should be measured at 500V d c each month If the reading is less than ten megohms the motor should be dried in a warm airflow typically 40 C and re checked before running the motor The fan should be o...

Страница 10: ...s than ten meghoms a break down in the motor winding insulation could be the reason and a motor rewind overhaul may be necessary Ensure that there is no smell of burnt insulation in the vicinity of th...

Страница 11: ...here no relevant harmonized standards exists Woods fans are driven by AC induction motors which are inherently compliant if supplied with a truly sinusoidal AC supply Where the fan motor is supplied v...

Страница 12: ...retaining plate Replace the 130mm Duramid seal if it is damaged 9 Examine the clearance between the fan impeller blade tips and the fan duct Check the angle and the security of the impeller blades Ens...

Страница 13: ...pply to Series 33 Bifurcated JM fans 10 FIGURE 1 FIGURE 2 A STANDARD TWO STAGE CONTRA ROTATING AXIAL FAN COMPRISES A FORM A RIGHT HAND FAN FOLLOWED BY A FORM B LEFT HAND FAN This does not apply to ide...

Страница 14: ...D1705 CD1706 CONTROLLER CONTROLLER CONTROLLER CONTROLLER FAN FAN FAN FAN CD1709 CD1708 PN 502271 PN 502260 PN 502273 PN 502261 1 PHASE 1 PHASE 1 PHASE 1 PHASE SPEED CONTROL WARNING SPEED CONTROL WARNI...

Страница 15: ...SE WEG MOTORS CD2426 FAN CD1653 CD1654 CD1656 CD1655 CONTROLLER CONTROLLER CONTROLLER CONTROLLER 1 PHASE 1 PHASE 1 PHASE 1 PHASE FAN FAN FAN WIRING DETAIL SINGLE PHASE DIRECT DRIVE MOTOR WITH SPEED CO...

Страница 16: ...W1 W2 U2 V2 U1 V1 W1 W2 U2 V2 U1 V1 W1 W2 U2 V2 U1 V1 W1 W2 U2 V2 U1 V1 W1 W2 U2 V2 U1 V1 W1 PN 83771 PN 83772 CD 1344 1 PN 407941 CD 1559 WIRING DETAIL THREE PHASE FANS WITH DUCT MOUNTED TERMINAL BO...

Страница 17: ...PHASE 3 PHASE 3 PHASE CD1683 PN 502333 PN 502334 WIRING DETAIL THREE PHASE FANS USING TERMINAL BOX ON MOTOR CD1546 CD1547 CD1550 CD1545 WIRING DETAIL THREE PHASE MOTOR WITH ISOLATOR FITTED 14 U1 V1 W1...

Страница 18: ...57 U1 V1 W1 V2 U2 W2 3 PHASE 3 PHASE WIRING DETAIL THREE PHASE DIRECT DRIVE MOTOR WITH ELECTRONIC TYPE SPEED CONTROLLER U1 V1 W1 V2 U2 W2 3 PHASE 3 PHASE CD1659 CD1660 U1 V1 W1 V2 U2 W2 3 PHASE CD1660...

Страница 19: ...DRAWING OF TORQUE SETTINGS FOR FIXINGS FIGURE 13 16...

Страница 20: ...fety With market presence in 65 countries we are in a unique position to be a local supplier and an international partner in our customer s projects Our product brands such as SEMCO eQ eQ Prime JM Aer...

Отзывы: