Climate zone
Savings (kWh/year)
Cold
8432
Average
4310
Warm
1949
Climate zone
SEC
Energy class
Cold
-73.2
A+
Average
-32.0
B
Warm
-8.4
F
(a) Brand
FläktGroup
(b) Model designation
MiniMASTER
RDKS
(c) Specific energy use (SEC)
(d) Unit type
Bidirectional
(e) Drive unit
Stepless speed controller, stepless adjustment
(f) Heat recovery system
Regenerative rotary energy recovery
(g) Thermal efficiency
80.5%
(H) Maximum airflow
209 m
3
/h
(i) Additional fan output, maximum flow
128 W
(j) Sound power level
37 dB(A)
(k) Reference flow
0.041 m
3
/s
(l) Reference pressure difference
50 Pa
(m) Specified additional output
0.39 W/m
3
/h
(n) Control type
Time control
(o) Air leakage
2.9% (external
3.5% (internal)
(p) Mixing rate
Not applicable
(q) Visual filter alarm
Filter alarm ISYteq Touch 3.5
(r) Instructions exhaust air grille
Not applicable
(s) Web address for dismantling and installation
http://flaktgroup.com
(t) Airflow sensitivity
Not applicable
(u) Air tightness, unit not connected to duct
Not applicable
(v) Annual electricity consumption
440 kWh/year
(w) Annual heating saved
MiniMASTER RDKS + ISYteq Touch 3.5
PRODUCT INFORMATION IN ACCORDANCE WITH COMMISSION REGULATION
(EU) NO. 1254/2014 ANNEX IV AS REFERRED TO IN ARTICLE 3(1b)
FläktGroup DC-9845SE 20180122_R2