OPERATION WITH EXTERNAL POWER SUPPLY

Prior to each use, carefully wash your hands and clean your Wi Neb according to the instructions provided in 

the “CLEANING, SANITIZATION AND DISINFECTION” section. During the application you should use adequate 

protection against any drips. The average lifespan of accessories is 1 year; however, we recommend you replace 

the nebulizer every 6 months in intensive use (or earlier, if the nebulizer is blocked) to always ensure maximum 

therapeutic effect. The nebulizer and accessories are for personal use only to prevent possible risk of infection 

HOW TO CONNECT THE ACCESSORIES

due to contamination. 

Use original FLAEM accessories only.

This device is suitable for the administration of me-

dical substances and not, for which the administra-

tion via aerosol is foreseen; these substances are to 

be in any case prescribed by the Doctor. In case of 

too thick substances, the dilution with a suitable 

physiological solution could be needed, according 

to the medical prescription.
Connect one end of the connection hose (E) to the 

device.
Connect the other end of the hose (E) to the L-fitting (F).
Connect the L-fitting (F) to the nebulizer (G).

Insert the nebulizer (G) in its housing on the device 

(A).

Open the nebulizer by turning the lid anticlockwise.

Pour in medication.

Содержание Wi.Neb P0209EM

Страница 1: ...Wi Neb IT MANUALE ISTRUZIONI D USO EN INSTRUCTIONS FOR USE H I L G F E C B D A N M 12V DC plug G G 4 G 1 G 2 G 3 Schema di collegamento Connection diagram...

Страница 2: ...ETTORE DIVELOCIT CONVALVOLA H NASALE NON INVASIVO I BOCCAGLIO L MASCHERA PEDIATRICA M MASCHERA ADULTI N BORSA PER ILTRASPORTO ENGLISH DESCRIPTION COMPONENTS A DEVICE MAIN UNIT B UNIVERSALPOWERADAPTOR...

Страница 3: ...da superfici calde Tenete il cavo di alimentazione dell alimentatore lontano dagli animali ad esempio roditori altrimenti tali animali potrebbero danneggiare l isolamento del cavo di alimentazione Non...

Страница 4: ...Inserire lo spinotto a L del cavetto dell alimenta tore nella presa DC plug dell apparecchio Inserire la spina del cavo nell apposita presa per accendisigari 12V DC dell auto camper barca Veri ficare...

Страница 5: ...rischi di infezione da contagio COLLEGAMENTO ACCESSORI Utilizzate solo accessori originali Flaem Questo apparecchio adatto per la somministra zione di sostanze medicinali e non per i quali prevista la...

Страница 6: ...riducendo al minimo la dispersione dello stesso nell ambiente circostante grazie al sistema val volare di cui l ampolla il boccaglio la mascherina sono dotate Accendere l apparecchio premendo l interr...

Страница 7: ...ssori disinfettabili sono G 1 G 2 G 3 G 4 H I L M Procurarsi un disinfettante di tipo clorossidante elettrolitico principio attivo ipoclorito di sodio specifico per disinfezione reperibile in tutte le...

Страница 8: ...so vengano utilizzati ricambi o accessori non originali Per rimuovere il coperchio AIR FILTER fate leva con una piccola moneta di dimensioni adeguate inserendola nella fessura posteriore Estraete il f...

Страница 9: ...simo alla temperatura ambiente Verificate che la quantit di liquido sia almeno 2 ml Se l apparecchio non nebulizza Verificate la presenza del medicinale nell ampolla Controllate che l ugello dell ampo...

Страница 10: ...12V DC ACO 211P Apparecchio mod P0209EM Alimentazione 12V DC Assorbimento 1 25 A Pressione Max 2 0 3 bar Portata aria al compressore 9 l min approx Rumorosit a 1 m 52 dB A approx Funzionamento 30 minu...

Страница 11: ...endisigari 12V DC In caso di rottura del fusibile che si trova nella spina di collegamento sostituite con un fusibile omologato da 3A Smaltimento dell apparecchio In conformit alla Direttiva 2012 19 C...

Страница 12: ...senza alcun preavviso SIMBOLOGIE Apparecchio di classe II Fabbricante Limite di temperatura Parte applicata di tipo BF Corrente alternata Limite di pressione atmosferica Attenzione controllare le istr...

Страница 13: ...power cable away from animals for example rodents which could damage the insulation Do not handle the power adaptor with wet hands Do not use the device in humid environments e g while taking a bath o...

Страница 14: ...ck of the power adaptor cable in the DC plug of the device Insert the cigarette lighter plug in the 12V DC ci garette lighter receptacle of the vehicle camper boat Check the User Manual of the vehicle...

Страница 15: ...possible risk of infection HOW TO CONNECT THE ACCESSORIES due to contamination Use original FLAEM accessories only This device is suitable for the administration of me dical substances and not for wh...

Страница 16: ...ication and reduces dispersion of the medication into the surrounding environment to a minimum thanks to the valve system provided in the nebulizer mouthpiece and mask Turn on the device by pressing t...

Страница 17: ...entation Fill a container big enough to hold all of the parts to disinfect with a solution of potable water and disinfectant according to the proportions indicated on the packaging of the disinfectant...

Страница 18: ...m any liability in the event of using non original spare parts or accessories To remove the AIR FILTER cover insert a small coin in the rear slot and gently pry open Remove the dirty filter using hous...

Страница 19: ...ature Check that there is at least 2ml of medicine in the nebulizer If the device provides no mist Check for medicine in the nebulizer Check that the nebulizer nozzle is not clogged Check that the air...

Страница 20: ...eptacle ACO 211P Device mod P0209EM Power supply 12V DC Absorption 1 25 A Max Pressure 2 0 3 bar Compressor air output 9 l min approx Noise level at 1 m approx 52 dB A Operation 30 minutes ON 30 minut...

Страница 21: ...Primary 100 240V 50 60Hz Secondary 12V DC 1 5 A Power cord for 12V DC cigarette lighter receptacle If the fuse inside the connection plug blows replace with 3A Disposal of device In conformity with D...

Страница 22: ...product without prior notice 22 ENGLISH SYMBOLS Class II device Manufacturer Temperature limit Tipe BF applied part Alternate current Atmospheric pressure limit Important check the operating instructi...

Страница 23: ...ITALIANO 23...

Страница 24: ...postale e o portato al Centro di Assistenza Tecnica Autorizzato vedi http www flaemnuova it it info assistenza allegando il presente tagliando debitamente compilato e lo scontrino fiscale o fattura d...

Отзывы: