12
INSTRUCTIONS FOR USE
1. Always disconnect the power cable (2.1) before topping up the device.
2. To remove the heating unit (2) see (fig. B), press it downwards (B1), simultaneously turning it anti-
clockwise (B2) and then remove it (B3) from the tank (1).
3. Fill the tank (1) with running water up to the Maximum level indicator on the tank (1.1) (Max. 4.5
litres).
4. Insert heating unit 2 inside tank 1.
4.1 Ensure that the fins (2.4) on the heating unit correspond with the slits (1.2) on the tank.
4.2 Rotate clockwise until it comes to a complete stop.
5.
WARNING: to prevent damage to the humidifier, DO NOT POUR the aromatic essences di-
rectly into the water tank (1).
Pour the aromatic essences into the essence container (2.2) (fig. E).
Pay attention to prevent over flows, and fill the container up to the level indicated (2.2).
6. Insert the plug into the socket corresponding to the device voltage in order to switch the night
light on (2.7).
7. Adjust the steam flow by moving the steam flow shutter (2.3) forwards and backwards (fig. F).
8. When there is no water in the tank, the ON/OFF night light (2.7) switches off. Unplug it from the
socket and wait 10 minutes for it to cool down before performing a new operation from (point 1).
NOTES: During operation, you may hear a gentle bubbling sound.
- The humidifier also includes a safety switch that switches the unit off when the tank runs out
of water or if the unit runs in dry operation.
- To restart the humidifier, disconnect the plug and wait 5 minutes for it to cool down. Top up
with water and restart from (point 4).
MAINTENANCE AND CLEANING
Always disconnect the power cable (2.1) and wait 30 minutes for the device to cool down, before
cleaning. For ex-tended periods of non-use, store the device, only when it is clean and dry, inside its
box.
ATTENTION: Presence of excessive scale may be found on the resistance due to lack of or poor
maintenance and cleaning operations. This may be the cause of malfunctions on the ON/OFF
night light (2.7) even when the tank is full.
Daily cleaning/maintenance:
1- Remove the heating unit (2) by rotating it and pulling it upwards (Fig. B).
2- Fully drain the tank. Ensure that water drains from the hole (1.3) (Fig. G).
3- Before refilling the tank, clean and rinse a couple of times with abundant water. If you do not use
it immediately, drain and dry with a cloth.
Warning:
DO NOT use abrasive detergents or brushes. DO NOT leave water in the water tank when
the device is not running. This prevents bacteria from forming in the tank.
Weekly cleaning/ maintenance:
1- On a weekly basis, clean the humidifier as described in “Daily cleaning”.
2- Clean the heating unit. Immerse the heating unit into 10 cm of solution containing 50% water and
50% white vinegar for 10 minutes. Lastly, rinse abundantly with hot water (approximately 40 °C)
see (Fig. H).
End of season cleaning/maintenance:
1- Clean the humidifier as described in “Weekly cleaning”.
2- Descale the resistance (2.6), by removing the cap of the heating unit (2.5) rotating it anti-clockwise
(fig. I). Use a regular sponge to remove the scale (fig. L).
Содержание HE21E00
Страница 40: ...39 EL Flaem www flaemnuova it 1 2 1 1 1 1 2 IN OUT 1 3 2 2 1 2 2 2 3 2 4 IN OUT 2 5 2 6 2 7 ON OFF FLAEM FLAEM...
Страница 41: ...40 8 2 DC...
Страница 42: ...41...
Страница 44: ...43 1 2 2 6 2 5 I L ON OFF 2 7 5 MAX 1 1...
Страница 45: ...44 2014 35 EU P0413ED 25 m2 220 240V 50Hz 240 260W 10 40 C cm 27 L x 29 P x 22 H 1 3 Kg 4 5 14...
Страница 52: ...51 8 2...
Страница 53: ...52 www Flaem flaemnuova it 1 2 1 1 1 2 1 3 1 FLAEM 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 AR...
Страница 55: ...54...
Страница 56: ...55 EU 2014 35 P0413ED 2 25 240 260 50 220 240 104 50 40 10 x 22 x 29 27 1 3 4 5 14...
Страница 57: ...56 7 2 5 1 1 1 50 10 2 40 10 50 1 5 2 6 2 2...
Страница 58: ...57...
Страница 59: ...58...