The  surface  on  which  the  unit  is  placed  in 
support must have the necessary stability  and 
strength  in  regard  of  the  safety  of  the 
operation. 

-

 

The load must be in free suspension. 

  With  this  arrangement,  never  lift  the  load 

without  having  placed  it  beforehand  at  the  vertical 
of the hoist. 
 
2.1.4

 

Reeving for lifting of load 

Use the reeving kit ref 540155. 
This  assembly  allows  you  to  double  the  capacity 
(working load 990 Kg) of the device. In return, the 
speed is decreased by half. 

 The LM must not be otherwise than with this 

reeving  kit  assembled.  Additional  system  must  not 
be added. 
The reeving kit  consists of an anchor carrier strand 
and a reeving block with a hook and a spring. 
 
The  user  should  note  that  when  reeving,  the 
required length of wire rope is at least twice the lift 
height,  plus  at  least  1  meter  of  apparent  slack 
strand. 
 
The  limit  spring  mounted  on  the  lower  pulley  is 
intended to replace the high limit stop. 
A  stop  may  still  be  placed  on  the  loose  strand  to 
serve as low end stopper. 
 

 In case of reeving, double the maximum load 

to  be  taken  into  account  for  the  calculations  of 
security. 
 
NOTA : take care to mount the pulley block so that 
its  limit  spring  is  located  on  the  cable  between  the 
pulley and the entry in the hoist (see figure). 

 

  Check  the  triggering  of  your  travel  limit 

switch  before  use;  a  repositioning  of  the  stoppers 
may be necessary depending on the configuration of 
job. 

 Check the capacity of the anchoring points. 

 
When operating with the reeving system, especially 
the operator  will ensure  that the load is not turning 
on  itself,  to  avoid  tangling  the  three  strands  of  the 
cable (two strands loaded and the slack side). 
Stop  immediately  if  the  loose  strand  comes  to 
tangle with the other strands. 
 
2.1.5

 

Power 

The  installer  must  ensure  that  the  power  supply  is 
compatible with the specification of the winch. 

 

 

The  power  supply  must  be  protected 

upstream  by  a  30  mA  differential  switch.  The 
installation  must  be  in  accordance  with  EN  60204-
1. Power outlets must be calibrated to 16A. 

Содержание LM500+

Страница 1: ...INSTRUCTION MANUAL Electrical winches LM500 R f 1813000204 Page 1 16 Version 44 16 INSTALLATION USE MAINTENANCE Monitoring of updates Date Description 03 11 2016 Creation...

Страница 2: ...CONTROL STATION 10 2 4 NORMAL USE 10 2 5 DECOMMISSIONING 11 2 6 WARNINGS ABOUT CONTRAINDICATIONS 11 2 7 RESIDUAL RISKS 11 2 8 TRANSPORTATION HANDLING STORAGE 11 3 MAINTENANCE SETTINGS 11 3 1 MAINTENAN...

Страница 3: ...facades The winch uses one steel cable hoisting cable The drive system consists of a pulley whose throat has a special profile and in which the cable is tight under the effect of the load by two artic...

Страница 4: ...tics of the cables used the number of hours the cables are used a record of incidents and actions taken to remedy them forecast dates of periodic inspections and record of actual dates of inspections...

Страница 5: ...hoisting cable into the device before the anchoring operation 2 Installation and Use 2 1 Instructions for installation assembly commissioning and use training Installation and use operations must be...

Страница 6: ...cial precautions The bearing surface on which the unit is placed must be flat and horizontal This surface must have a minimum 120mm orifice for the passage of the two strands of cable The device must...

Страница 7: ...n the lower pulley is intended to replace the high limit stop A stop may still be placed on the loose strand to serve as low end stopper In case of reeving double the maximum load to be taken into acc...

Страница 8: ...ime in case of imminent danger or need press the Punch red button to stop any movement of your hoist 2 1 6 Installation of cables for lifting Use protective gloves when handling wire rope Check the co...

Страница 9: ...Ensure that the outgoing winch cable slack is free Do not let the loaded rope become slack if the load is not stable resting on a strong enough support 2 2 Diagrams and safety explanations Installatio...

Страница 10: ...very 45 minutes of work to avoid overheating 2 3 Description of the work or control station Up and down hoist movements are controlled from the pendant control Never stand under the load In case of a...

Страница 11: ...containing bisulphite or MoS2 Molykote etc To apply a load on the loose strand of the hoist To use the wire rope as a means to sling the load 2 7 Residual risks The use of cable damaged or not suited...

Страница 12: ...ssing the 8 pivot After each operation a load test must be performed FIXATOR or its dealers can train your staff for the maintenance of your winches For your safety and to benefit from the full guaran...

Страница 13: ...or is activated The motor is blocked The contactors in the hoist are off or disconnected Error in the control circuit Error in the power circuit Wait until it cools Check the motor Reconnect or change...

Страница 14: ...opper ref 462030 Capacitor ref 540144 Pendant control ref 462020 Motor cap ref 462021 Fuse ref 244612 3 4 Disposal Disassembly and disposal of the hoist must be in accordance with the current regulati...

Страница 15: ...INSTRUCTION MANUAL Electrical winches LM500 R f 1813000204 Page 15 16 Version 44 16...

Страница 16: ...Page 16 16 Version 44 16 The original of this document is in French no translation can replace it P A 8 rue du Bois Rinier B P 10041 49181 ST BARTHELEMY D ANJOU France TEL 33 0 2 41 31 17 00 FAX 33 0...

Отзывы: