2.2.2

 

Safety devices 

-

 

A  main  brake  acts  on  the  engine  in  case  of 
power supply failure 

-

 

An  upper  limit  switch  sensor  stops  lifting 
when the spring touches the plate. 

-

 

A  lower  limit  switch  sensor  stops  lowering 
when the spring touches the plate. 

-

 

An  electrical  emergency  stop  placed  on 
pendant  control  acts  immediately  and  stops 
the winch to the ascent and the descent. 

-

 

Mechanical 

locking 

prohibiting 

the 

simultaneous  action  of  the  up  and  down 
commands. 

-

 

Electrical  protection  of  the  pendant  control  : 
class 2. 

-

 

Fuse protecting the command, in the electrical 
box. 

-

 

Hooks with safety latch. 

 
The  230V  single-phase  motor  is  protected  against 
excessive  warm-ups  by  a  probe  inserted  into  the 
coil.  This  probe  prohibits  operation  by  interrupting 
the control circuit as long as the temperature of the 
coil  is  not  back  to  an  acceptable  value.  In  case  of 
intensive  work  or  high  duty,  we  suggest  to  allow  a 
15 minutes break every 45 minutes of work to avoid 
overheating. 
 
2.3

 

Description of the work or control station 

"Up"  and  "down"  hoist  movements  are  controlled 
from the pendant control. 

 Never stand under the load. 

In  case  of  a  command  error,  wait  for  a  complete 
stop  of  motion  before  performing  another 
command.  The  control  buttons  are  held  type 
buttons. 
Limit  stops  are  not  operating  devices  but  safety 
devices.  They  should  therefore  not  be  used 
voluntarily but only serve as shutoff devices in case 
of involuntary exceedance of the expected travel. 
Never stay or work under load. If necessary, have a 
barrier of security on the floor around the area at the 
vertical of the load. 

  Avoid  heavy  slipping:  Wait  for  a  complete 

stop 

of 

your 

installation 

before 

resuming 

movement. 
Check regularly that no obstacle is located along the 
path of movement (above and below the load). 
 
2.4

 

Normal use 

This hoist is designed for lifting loads. 

It  is  designed  for  professionals  involved, 
for  example,  in  work  in  elevator  shafts  or 
on façades. 
 
Press on  « » to lift and on  « » to lower. 
Release  the  buttons  to  stop  the  movement. 
If  it  is  not  stopped,  press  the  Emergency 
Stop. If it is not working, remove the main 
plug and have your hoist maintained. 
 

Содержание LM500+

Страница 1: ...INSTRUCTION MANUAL Electrical winches LM500 R f 1813000204 Page 1 16 Version 44 16 INSTALLATION USE MAINTENANCE Monitoring of updates Date Description 03 11 2016 Creation...

Страница 2: ...CONTROL STATION 10 2 4 NORMAL USE 10 2 5 DECOMMISSIONING 11 2 6 WARNINGS ABOUT CONTRAINDICATIONS 11 2 7 RESIDUAL RISKS 11 2 8 TRANSPORTATION HANDLING STORAGE 11 3 MAINTENANCE SETTINGS 11 3 1 MAINTENAN...

Страница 3: ...facades The winch uses one steel cable hoisting cable The drive system consists of a pulley whose throat has a special profile and in which the cable is tight under the effect of the load by two artic...

Страница 4: ...tics of the cables used the number of hours the cables are used a record of incidents and actions taken to remedy them forecast dates of periodic inspections and record of actual dates of inspections...

Страница 5: ...hoisting cable into the device before the anchoring operation 2 Installation and Use 2 1 Instructions for installation assembly commissioning and use training Installation and use operations must be...

Страница 6: ...cial precautions The bearing surface on which the unit is placed must be flat and horizontal This surface must have a minimum 120mm orifice for the passage of the two strands of cable The device must...

Страница 7: ...n the lower pulley is intended to replace the high limit stop A stop may still be placed on the loose strand to serve as low end stopper In case of reeving double the maximum load to be taken into acc...

Страница 8: ...ime in case of imminent danger or need press the Punch red button to stop any movement of your hoist 2 1 6 Installation of cables for lifting Use protective gloves when handling wire rope Check the co...

Страница 9: ...Ensure that the outgoing winch cable slack is free Do not let the loaded rope become slack if the load is not stable resting on a strong enough support 2 2 Diagrams and safety explanations Installatio...

Страница 10: ...very 45 minutes of work to avoid overheating 2 3 Description of the work or control station Up and down hoist movements are controlled from the pendant control Never stand under the load In case of a...

Страница 11: ...containing bisulphite or MoS2 Molykote etc To apply a load on the loose strand of the hoist To use the wire rope as a means to sling the load 2 7 Residual risks The use of cable damaged or not suited...

Страница 12: ...ssing the 8 pivot After each operation a load test must be performed FIXATOR or its dealers can train your staff for the maintenance of your winches For your safety and to benefit from the full guaran...

Страница 13: ...or is activated The motor is blocked The contactors in the hoist are off or disconnected Error in the control circuit Error in the power circuit Wait until it cools Check the motor Reconnect or change...

Страница 14: ...opper ref 462030 Capacitor ref 540144 Pendant control ref 462020 Motor cap ref 462021 Fuse ref 244612 3 4 Disposal Disassembly and disposal of the hoist must be in accordance with the current regulati...

Страница 15: ...INSTRUCTION MANUAL Electrical winches LM500 R f 1813000204 Page 15 16 Version 44 16...

Страница 16: ...Page 16 16 Version 44 16 The original of this document is in French no translation can replace it P A 8 rue du Bois Rinier B P 10041 49181 ST BARTHELEMY D ANJOU France TEL 33 0 2 41 31 17 00 FAX 33 0...

Отзывы: