INSTRUCTION MANUAL
Electrical winches LM500+
Réf : 1813000204
Page :
6/16
Version : 44/16
The resistance of the pulley and its
anchorage must be calculated for a double effort of
the load.
2.1.3
Installation support on a basis
Use the optional ref 461021.
This type of installation requires special
precautions:
-
The bearing surface on which the unit is
placed must be flat and horizontal.
-
This surface must have a minimum Ø120mm
orifice for the passage of the two strands of
cable,
-
The device must be positioned so that the
lifting wire rope, under load, does not rub
against the walls of the hole, and so that the
travel end stoppers on the wire rope can come
in contact with the switch levers.
-
The device must be propped so that it will not
move on the support. (4 drillings Ø13
available)