background image

 

INSTRUCTION MANUAL 

Electrical winches LM90A/LM250A

 

Réf : 1813000156 
Page : 

11/17

 

Version : 23/21 

- with 

lubricated 

cables 

with 

products

containing  bisulphite  or  MoS2  (Molykote  ®,
etc)

- To  apply  a  load  on  the  loose  strand  of  the

hoist.

- To  use  the  wire  rope  as  a  means  to  sling  the

load

2.7

 

Residual risks 

The  use  of  cable  damaged  or  not  suited  to  the 
device is the major risk of accident and failure. 

  Check  that  your  equipment  has  not  been 

subject to vandalism, theft, or damage. 

 Never disable the safety features. 

 Never swing a load voluntarily. 

 Do not block a control. 

  In  case  of  continuous  operation  for  more 

than 15 ', the surface temperature of the motor  can 
begin to rise significantly. 

2.8

 

Transportation, handling, storage 

To transport your machine from one site to another, 
remove the cables from your hoist. 
Store the various components of your equipment in 
a clean and dry place. 

3

 

Maintenance - Settings 

  Maintenance  operations  must  be  performed 

by  personnel  specially  trained  by  the  manufacturer 
or its dealers. 

3.1

 

Maintenance operations 

LM hoists must be reviewed at least once a year and 
every  100h.  In  harsh  environments  (sandblasting, 
marine, back and forth operation at full load, doubts 
about  the  proper  use  etc)  a  higher  frequency  of 
verifications may be required. 
Load  lifting  winches  are  intended  for  a  limited 
lifetime;  beyond  that,  a  return  to  factory  is 
imperative. 
For the hoist LM  
type LM90A, the ranking is A2. 
type LM250A, the ranking is A1. 

In  some  countries,  periodic  audits  and  reviews  of 
commissioning are mandatory. 

3.1.1

 

Preventive maintenance 

  These  operations  must  be  performed  by  a 

competent  person  trained  by  FIXATOR  or  its 
dealers. The FIX022 manual details these annual or 
control operations. 

Check: 
Daily : 
The  quality  of  your  anchors  and  of  the  2  hooks 
(latch). 
The  good  clamping  of  the  travel  end  stoppers  on 
your cable. 
The good general condition. 

Monthly : 
The  proper  functioning  of  the  safety  devices 
(emergency stop, limit switches, brake). 
The good condition of the wire rope (§3.1.3) 
The overall proper functioning by performing a full 
movement at the rated load. 

Every year and every 100h : 
Check the groove pulley. 
Check the bearings, rudder, gear... 
Check the motor brake. 
Control each security (cf §2.2.2) at the rated load. 
Clean  and  grease  the  gears  (e.g.  BIMO  EP  or 
Klubersynth AG14-61) 

Содержание LM250A

Страница 1: ...MANUAL Electrical winches LM90A LM250A R f 1813000156 Page 1 17 Version 23 21 INSTALLATION USE MAINTENANCE Monitoring of updates Date Description 08th Jun 2021 New format type A for Radio option modif...

Страница 2: ...ARNINGS ABOUT CONTRAINDICATIONS 10 2 7 RESIDUAL RISKS 11 2 8 TRANSPORTATION HANDLING STORAGE 11 3 MAINTENANCE SETTINGS 11 3 1 MAINTENANCE OPERATIONS 11 3 1 1 Preventive maintenance 11 3 1 2 Adjusting...

Страница 3: ...r work such as in an elevator shaft or on building facades The winch uses one steel cable hoisting cable The drive system consists of a pulley whose throat has a special profile and in which the cable...

Страница 4: ...a record of incidents and actions taken to remedy them forecast dates of periodic inspections and record of actual dates of inspections 1 6 Recommendations for use and general safety Before using thi...

Страница 5: ...r the effort to apply If the anchoring is not provided by FIXATOR each anchor must withstand without any deformation up to 2 5 times the WLL of the winch that is 2 5x90 225 kg respectively 2 5x250 625...

Страница 6: ...ualified technician 2 1 1 Suspended installation It s the simplest mounting and the most common Device in suspension and direct traction or lifting The anchoring of the device must be done exclusively...

Страница 7: ...ft height plus at least 1 meter of apparent slack strand The limit spring mounted on the lower pulley is intended to replace the high limit stop A stop may still be placed on the loose strand to serve...

Страница 8: ...e main power plug 2 1 4 2 Commissioning Unlock the emergency stop if necessary Press the UP button to lift or pull the load Press the DOWN button to lower the load At any time in case of imminent dang...

Страница 9: ...t the outgoing winch cable slack is free Do not let the loaded rope become slack if the load is not stable resting on a strong enough support 2 2 Diagrams and safety explanations Installation and use...

Страница 10: ...he load Avoid heavy slipping Wait for a complete stop of your installation before resuming movement Check regularly that no obstacle is located along the path of movement above and below the load 2 4...

Страница 11: ...ust be reviewed at least once a year and every 100h In harsh environments sandblasting marine back and forth operation at full load doubts about the proper use etc a higher frequency of verifications...

Страница 12: ...ly original FIXATOR parts ask the complete list of spare parts 3 1 3 Lubricating controling a hoist cable The hoisting cable must be regularly greased or lubricated with Teflon For this use for exampl...

Страница 13: ...ensor is activated The motor is blocked The contactors in the hoist are off or disconnected Error in the control circuit Error in the power circuit Wait until it cools Check the motor Reconnect or cha...

Страница 14: ...nd stopper ref 540620 Capacitor 40uF ref 540582 Pendant control ref 461020 Motor cap ref 540601 Fuse ref 244612 3 4 Disposal Disassembly and disposal of the hoist must be in accordance with the curren...

Страница 15: ...INSTRUCTION MANUAL Electrical winches LM90A LM250A R f 1813000156 Page 15 17 Version 23 21...

Страница 16: ...ntensity of use 4 2 1 Model ref 461025 This model follows the recommendations of EN60204 32 2008 It contains a transmitter IP65 and a receiver with internal antenna IP66 range 75 to 100m Frequency ban...

Страница 17: ...6 Page 17 17 Version 23 21 The original of this document is in French no translation can replace it P A 8 rue du Bois Rinier B P 10041 49181 ST BARTHELEMY D ANJOU France TEL 33 0 2 41 31 17 00 FAX 33...

Отзывы: