THROUGH THE WALL UNIT
21
PTTW CONTROL SPECIFICATIONS
1. ABBREVIATIONS
ST = Setting temperature
RT = Room air temperature
IPT = Indoor coil temperature
OPT
= Outdoor coil temperature
PTC data = R25-5.00KOhm±1% B25/50=3470K±1%
2. CONTROL SYSTEM OPERATION
2.1. REMOTE HANDSET AND ON-BOARD PANEL OPERATION
2.1.1. REMOTE HANDSET FUNCTIONS
Remote handset functions are Unit ON/OFF, Mode, Fan Speed, Set Temperature, Swing
Function, Timer ON, Timer OFF, Electric heater and Sleep Function
2.1.2. ON-BOARD PANEL FUNCTIONS
On-board panel functions are Unit ON/OFF, Mode, Fan Speed, Set Temperature and Electric
heater.
2.2. MODE INTRODUCTION
2.2.1 AUTO MODE
After turning the unit on, select the auto mode. The unit will select its operation mode by
judging room temperature (see below table):
Indoor temp.
Indoor
≤
20
℃
20
℃<
indoor
<
25
℃
Indoor
≥
25
℃
Operating mode
HEATING
FAN
COOLING
Standard fixed setting
temperature
20
℃
22
℃
25
℃
2.2.2 COOLING MODE
2.1.2.1 Setting temperature
:
18
℃
-30
℃
.
2.1.2.2 Working conditions of compressor
:
a. Compressor works when RT
≥
ST+1
℃;
Содержание PTTW-10-EC Series
Страница 1: ...ENGINEERING MANUAL PTTW 10 EC SERIES THROUGH THE WALL AIR CONDITIONERS 2010 EU V 1 1 ...
Страница 7: ...THROUGH THE WALL UNIT 6 Noise Level Indoor Fan Mode ...
Страница 8: ...THROUGH THE WALL UNIT 7 Noise Level Indoor Cooling Mode ...
Страница 9: ...THROUGH THE WALL UNIT 8 Noise Level Outdoor Cooling Mode ...
Страница 10: ...THROUGH THE WALL UNIT 9 OPERATION TEST PTTW 10 Cooling test ...
Страница 11: ...THROUGH THE WALL UNIT 10 PTTW 10 Heating test ...
Страница 12: ...THROUGH THE WALL UNIT 11 PTTW 10 Heating test ...
Страница 13: ...THROUGH THE WALL UNIT 12 PTTW 10 Heating test ...
Страница 14: ...THROUGH THE WALL UNIT 13 EXPLODED DRAWING ...
Страница 19: ...THROUGH THE WALL UNIT 18 ELECTRIC WIRING DIAGRAM For PTTW 10 ...
Страница 34: ...THROUGH THE WALL UNIT 33 THIS IS THE END ...