background image

CONTROL PANEL

4

The ID Excel control panel is an all new digital I/O System.  The LCD 

Display provides you with a constant control readout showing you 

all of your current settings. 

1.

 The POWER button turns the unit ON and OFF. One of the first 

things you will notice when you turn on your ID Excel is the battery 

level display. Fresh batteries will show 9 volts; when the battery 

level is down to 6 volts, you have about an hour of battery life 

left. The detector will not turn on if the search coil is not properly 

connected. This can prove to be a timesaving  safeguard.

2.

 The MENU button enables you to enter the “menu mode,” in 

which you can adjust the discrimination and sensitivity controls 

with the UP/DOWN arrow buttons. Notice that when the MENU 

button is pushed, the active control blinks — this is the control that 

can be adjusted with the UP or DOWN arrow buttons.  To move 

to the next control, just press the MENU button again.  When you 

have all your settings completed, press the P/P (Pinpoint) button 

to return to the search mode. 

Содержание M-Scope ID Excel

Страница 1: ...ID Excel Target I D Metal Detector F I S H E R R E S E A R C H L A B O R A T O R Y Operating Manual...

Страница 2: ...Factory Preset Mode pg 6 4 Tone Audio System pg 7 Pinpointing pg 7 LCD Identification System pg 8 Auto Ground Balance pg 9 Additional Features pg 10 Searching pg 11 Battery Replacement pg 13 Maintenan...

Страница 3: ...rior target separation and a 4 tone audio ID all in an easy to use lightweight package Read this instruction manual thoroughly practice often and you will be ready for some exciting and rewarding trea...

Страница 4: ...e ground about 6 to 12 inches in front of and slightly to the right of your right foot to the left of your left foot for left handers Your arm should be straight and relaxed the grip held loosely see...

Страница 5: ...ear the search coil may cause false signals but don t wrap it so tightly that it pulls against the housing or the coil SETTING UP 5 Reconnect the coil cable to the control housing Be careful not to cr...

Страница 6: ...out an hour of battery life left The detector will not turn on if the search coil is not properly connected This can prove to be a timesaving safeguard 2 The MENU button enables you to enter the menu...

Страница 7: ...TONE B The SENSITIVITY control can be varied from a setting of 1 to a maximum of 10 with the arrow buttons when the SENS icon is flashing As with most detectors set the sensitivity higher for best dep...

Страница 8: ...tion system activated To switch betweeen the two modes while hunting press the arrow down mode button Fisher recommends that for a quick start setup and while you are learning to hunt with your ID Exc...

Страница 9: ...curate I D When hunting in the ALL Metal mode a single tone will be heard for any metal object the coil is swept over This mode responds much like the auto tune mode of previous detectors Pinpointing...

Страница 10: ...indicates whether the target is ferrous in nature an iron target or nonferrous a non iron target The target I D numbers correspond to the following target types All negative numbers Iron 0 to 8 Foil 9...

Страница 11: ...for about 2 seconds Then while still holding the AUTO button down lift the coil about 6 inches off the ground hold for a second and release the button The ID Excel will give you a brief tone to let y...

Страница 12: ...sounding off an audio bell tone This lets you know that the object is too close to the coil for the 4 tone audio or LCD systems to accurately identify the object CONSTANT CONTROL READOUT Unlike many...

Страница 13: ...aximum coverage and depth If you re searching on a lawn you may set the coil right on the grass and lightly scrub it 3 Overlap your sweeps by at least 50 percent Remember that your coil s search patte...

Страница 14: ...und mineralization and search mode 1 Minimum depth a Very slow or very fast sweep speed b Highly mineralized soil 2 Good depth a Moderate sweep speed b Moderately mineralized soil 3 Maximum depth a Mo...

Страница 15: ...ng When it s time to replace the batteries always replace both of them 1 To open the battery compartments press gently down and out on the battery door latch The doors are tethered do not attempt to c...

Страница 16: ...original owner Your ID Excel doesn t require a lot of care It s built with high quality materials But there are a few things you should do to keep it in peak operating condition 1 If you re not going...

Страница 17: ...ery Alert Yes Type Two 9 Volt Alkaline 5 Life 20 25 hours Alkaline 2 LENGTH OPERATING MODES SEARCH COIL BATTERIES Lifetime Limited Warranty warranty may vary outside of the United States see your deal...

Страница 18: ......

Страница 19: ......

Страница 20: ...time of Service Satifaction Warranty may vary outside the United States See your dealer for details SERVICE Fisher is committed to providing you our valued customer with superior service Each and ever...