9.3.3.8 Temperature protection of compressor discharge (ODU P4)
Temperature
protection
of
compressor
discharge
Check
whether
the
compressor
discharge
temp.
is
more
than
115°C
?
Check whether the
connection is right between
compressor discharge temp.
sensor and PCB according
to wiring diagrams?
Measure the resistance value
of
compressor discharge
temp. sensor.
If the value is
not normal
is
normal refer
to
the
Appendix
2?
No
Yes
Yes
No
Correct the wiring connection
Stop
leaking
and
add
refrigerant
Replace the compressor discharge temp. sensor
No
Yes
Replace high pressure valve assy
Yes
No
Replace outdoor main PCB
No
Check
whether
the
refrigerant
is
leak