background image

Principle of Operation

VSX4 and VSX8 Series Controller

The pressure measuring element of the controller 

consists of a diaphragm that senses downstream 

pressure. The downstream pressure is controlled 

by the regulator. The top side of the diaphragm 

encounters the force imposed by the overpressure 

shut-off spring and underpressure shut-off spring.
When the downstream pressure increases above the 

Overpressure Shutoff (OPSO) setting, the diaphragm 

moves up.
When the downstream pressure decreases below the 

Underpressure Shutoff (UPSO) setting, the diaphragm 

moves down.

Both of these actions result in the rotation of the cam 

and the release of the reset pin.
The valve plug spring moves the valve plug against 

the regulator port, stopping the fl ow of gas. The reset 

button is then used to reset (relatch) the controller 

(refer to the Resetting Procedure section for detailed 

resetting instructions).

Standard downstream pressure registration for the 

controller is external; however, internal sensing line is 

made available by removing the downstream sense 

blocking screw, installing a 1/4 NPT plug in the control 

line port and removing the downstream control line.

DIAPHRAGM

CaM

CONTROL LINE PORT

RESET BUTTON

RESET PIN

VALVE PLUG

VALVE PLUG SPRING

DOWNSTREAM SENSE 

BLOCKING SCREW

OUTLET PRESSURE, P

d

INLET PRESSURE, P

u

ATMOSPHERIC PRESSURE, P

b

M1141

OVERPRESSURE SHUTOFF (OPSO) 

ADJUSTING SCREW

UNDERPRESSURE SHUTOFF (UPSO) 

ADJUSTING SCREW

UNDERPRESSURE 

SHUTOFF (UPSO) SPRING

OVERPRESSURE 

SHUTOFF (OPSO) SPRING

Figure 3.

 Type VSX8 Operational Schematic

VSX4 and VSX8 Series

5

Содержание EMERSON VSX4 Series

Страница 1: ...erformed by unqualified personnel may result in improper adjustment and unsafe operations which may result in equipment damage or personal injury Figure 1 VSX4 and VSX8 Series Controller The VSX4 and...

Страница 2: ...on Only Connections Controller Vent 1 4 NPT External Sensing Line 1 4 NPT Maximum Allowable Pressure PS 1 Differential Strength 20 0 bar 290 psig Integral Strength 6 0 bar 87 psig Specific Maximum All...

Страница 3: ...704 regulator type spring range Spring part number and color Minimum Maximum Typical Setpoint Under Pressure Shutoff Upso Over Pressure Shutoff Opso Spring Range Factory Set Spring Range Factory Set m...

Страница 4: ...o 1 57 bar 1 15 2 to 22 8 1 Pink 3 0 0 118 70 0 2 75 GF02172X012 1 25 to 2 30 bar 1 18 1 to 33 4 1 Green 3 4 0 134 70 0 2 75 GF02173X012 2 10 to 3 75 1 30 5 to 54 4 1 Silver 4 0 0 157 70 0 2 75 0 90 t...

Страница 5: ...oves the valve plug against the regulator port stopping the flow of gas The reset button is then used to reset relatch the controller refer to the Resetting Procedure section for detailed resetting in...

Страница 6: ...tings does not preclude the possibility of damage from external sources or from debris in the pipeline General Installation Instructions Note The VSX4 and VSX8 Series can be rotated 360 for easy insta...

Страница 7: ...line Slam Shut Device type VSX4 type vsx8 Slam Shut Device sense line RESET TRIP CLEARANCE 25 1 REMOVAL CLEARANCE 45 1 8 SPRING REMOVAL CLEARANCE 80 3 1 146 5 8 118 4 6 28 1 1 147 5 8 RESET TRIP CLEA...

Страница 8: ...w key 40 by turning it counterclockwise Remove and discard the UPSO spring key 38 and the mini washer key 103 Using a flathead screwdriver turn the OPSO adjusting screw key 43 clockwise until it stops...

Страница 9: ...or key 27 is visible and firm when pressed with a finger Controller in Closed Tripped Position Figure 12 When the controller is in the closed position the travel indicator key 27 is not visible and ea...

Страница 10: ...t off Button key 23 DOWNSTREAM CONTROL LINE CONNECTION 23 Figure 7 Controller Manual Bypass Figure 8 Controller Bypass with Screwdriver Manual Shut Off Button Procedure For VSX4 and VSX8 Series 47 30...

Страница 11: ...e 12 Controller in Closed Tripped Position Figure 9 Relatching the Controller Mechanism 30 Figure 10 Repositioning the Reset Button 26 Figure 11 Controller in Open Reset Position 27 VSX4 and VSX8 Seri...

Страница 12: ...r controller from system pressure and relieving all internal pressure Refer to Figure 13 when following this procedure Remove the body flange screws key 34 and the two half flanges key 36 Remove the c...

Страница 13: ...your local Sales Office Table 8 VSX4 and VSX8 Series Troubleshooting Using a 10 mm 0 394 in wrench unscrew and remove the eight spring case screws key 16 and associated nuts key 12 and then remove the...

Страница 14: ...012 43 OPSO Adjusting screw GF01923X012 44 Fastening ring not shown GF04079X012 46 Outlet O ring I 5370 54 0 x 2 0 GF03443X012 47 VSX4 Series Valve plug D24 Disk Medium capacity GF01940X012 47 VSX8 Se...

Страница 15: ...GF01927X012 14 1 Closing cap O ring GF03448X012 31 1 Lock nut FA404550X12 spring according to setpoint not included in the kit L1 L2 3 14 80 84 48 104 42 7 6 12 102 28 29 27 2 L2 L L1 L1 L1 L1 L2 23 2...

Страница 16: ...d Arab Emirates Tel 971 4811 8100 TESCOM Emerson Process Management Tescom Corporation USA Headquarters Elk River Minnesota 55330 2445 USA Tels 1 763 241 3238 1 800 447 1250 Europe Selmsdorf 23923 Ger...