Table 3. easy-Drive 200L Modbus Map (cont.)
Type
Name
MB Register
Default
R/W
Values
Notes
unit32
PCB test date
40132, 40133
0
R/W*
0-4,294,967,
296
Seconds since January 1, 2000,
Board Supplier Functional Test Date
unit32
Motor test date
40134, 40135
0
R/W*
0-4,294,967,
296
Seconds since January 1, 2000,
Motor Supplier Test Date
unit32
System completion date
40136, 40137
0
R/W*
0-4,294,967,
296
Seconds since January 1, 2000,
Final Assembly Test Date
UNIT16 – unsigned 16 bit variable, can take value 0-65535.
UNIT32 – unsigned 32 bit variable, can take value 0-4294967295.
(Reserved) – registers used for development use only.
† - 32bit register contains data that spans two registers – reads and write of data needs
to be performed within the same Modbus command function to ensure coherency of
data.