Fisher Scientific Isotemp RT Скачать руководство пользователя страница 44

 

 

 

 

 

 

8-2

 

 

Section 9   

Warranty Information

 

 

 

 

FISHER SCIENTIFIC STANDARD PRODUCT WARRANTY 

 

When used in laboratory conditions and according to these operation instructions and maintenance, this 
product is warranted for 24 months against defective materials or workmanship.   
The 24 month warranty period begins from the delivery date of this product. 
For product quality or performance issues, contact Fisher Scientific Customer Service. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание Isotemp RT

Страница 1: ...Operation Manual Isotemp RT Digital Hotplate 9240 11 012 V01 12 01 17...

Страница 2: ...This manual cover the model is shown below NA Model EU Model Voltage Description 11676257 15306607 230V EU UK ANZ CN Isotemp RT Dgtl HP230V 11676258 N A 120V US Isotemp RT Dgtl HP120V...

Страница 3: ...fications appearance and dimensions described in this document without notice Fisher makes no representations or warranties with respect to this manual In no event shall Fisher be held liable for any...

Страница 4: ...hese alerts are classified into four types in this manual depending on the importance and the risk levels as described below Symbols Meaning Indicates a hazardous situation which if not avoided will r...

Страница 5: ...e 4 2 Run Stop Button 4 2 Temperature Setting t mode 4 3 Temperature Setting r mode 4 4 Timer Setting 4 5 Lock Button 4 7 Enter Terminate Configuration Mode 4 7 Check Configuration Settings 4 8 Select...

Страница 6: ...n 5 2 Keeping Product 5 2 Section 6 Trouble Shooting 6 1 Section 7 Accessories 7 1 Assembly of Support Rod 7 1 Transparent Shield Heating Bath Assembly 7 2 Section 8 Technical Specifications 8 1 Dispo...

Страница 7: ...it under water Never reach for this equipment if it has fallen into water Check electrical requirements described in this operation manual or on the ID plate of this equipment before use Connect this...

Страница 8: ...not touch the power outlet power socket or power cord with wet hands And make sure to connect the power cord directly and firmly to the power outlet and power socket Do not put or insert any objects e...

Страница 9: ...y top plate Item Model Isotemp digital hotplate Dimension W x D x H mm 161 x 290 x 100 Top plate dimension 140 mm 5 5 Maximum heating capacity 600W Current consumption 230V 3A Current consumption 120V...

Страница 10: ...the auto tuned parameters to be used for temperature control Adjustment of the Heating Rate If needed you can adjust the heating rate ranging from 0 to 100 at 1 intervals Refer to Temperature Setting...

Страница 11: ...also stops heating to protect the motor and the PCB You will be alerted by both audible and visible signals will be activated In such cases turn off the power switch and disconnect the power cord firs...

Страница 12: ...the chances of contact with liquid spills or leakage Convenience Two large digital displays on the control panel clearly show both set and actual temperatures of the top plate side by side Easily set...

Страница 13: ...amic coated Top Plate 2 Heat Sink 3 Control Panel see Control Panel section 4 Heater Knob 5 Control Knob 6 Threaded Holes for Support Rods 7 Main Power Switch Figure 2 3 Back Components 8 Transparent...

Страница 14: ...ensure that all the following parts and accessories are included in the package If not contact your dealer or Fisher Scientific immediately Item Quantity Main body 1 Operation Manual 1 Power Cord 1 T...

Страница 15: ...dry and fireproof surface inside a lab with proper safety measures Observe the minimum distances in general 30 cm or 12 inches from other devices In addition any device which can be affected by the mo...

Страница 16: ...manual or on the ID plate attached to the bottom of this equipment before use Make sure to connect this equipment only to properly grounded as well as dedicated power outlets to protect you and your e...

Страница 17: ...Warning Indicator B Operational Status LEDs C Actual Temperature Display D RUN STOP Button E Temperature Setting Button F Timer Setting Button G Lock Button H Configuration Button see Configuration M...

Страница 18: ...switch the following display will appear in sequence 4 You can easily check the selected heating mode by checking the LED The T CTRL LED illuminates under the temperature priority mode The R CTRL LED...

Страница 19: ...f the top plate temperature is over 50 C Surface temperature may be hot Even if the instrument is turned off the surface of the top plate and the vessel on top of it will remain very hot for some time...

Страница 20: ...done properly check the low and high limits first See Changing the High and Low Temperature Limits You can set the low and high temperature limits at any value bet ween 0 C and 350 C Temperature Sett...

Страница 21: ...that the hour frame is blinking first as shown below 2 If you want to change the timer setting select and then save the desired values into the hour frame and the minute frame by turning the Control K...

Страница 22: ...following display Terminate the timer operation either by pressing the RUN STOP Button or by turning off the main power switch The allowed timer range is between 1 minute and 99 hour 59 minu tes You...

Страница 23: ...ert when the locking function is cancelled Enter Terminate Configuration Mode Various configuration settings can be adjusted under Configuration mode such as heating mode timer mode maximum heating ra...

Страница 24: ...tioned earlier the default configuration settings are as follows Display Default Setting Heating Mode type Temperature Priority Mode t Temperature Unit unit Celsius Cels Timer Mode time Immediate Time...

Страница 25: ...er checking the settings terminate the checking mode either by pressing the Control Knob or by pressing the RUN STOP Button 4 Terminate the configuration mode as described in Enter Terminate Configura...

Страница 26: ...n C F The desired temperature unit can be selected as follows 1 Press the CONFIG Button and select the temperature unit conversion by turning the Control Knob as shown at right 2 Press the Control Kno...

Страница 27: ...her hand timer is activated only when the set temperature is reached The timer mode selection procedures are as follows 1 Press the CONFIG Button and select the timer mode shown below by turning the C...

Страница 28: ...ng is 10 50C See Technical Specification for the temperature difference depend ing on the top plate temperature If for example the actual temperature of the top plate is 100 C but the displayed temper...

Страница 29: ...certain degree by limiting maximum heating rate When the heat up time is too slow check whether the maximum heating rate is set too low If for example the current heating rate is 100 but you want to...

Страница 30: ...perature Limits Note that the default setting of the low temperature limit t L is 0 C and the high temperature limit t h 350 C If needed however you can set your own temperature limits If for example...

Страница 31: ...l Knob as shown below 4 14 Section 4 Operation Change the High Low Temperature Limits continued 5 Terminate the configuration mode as described in Enter Terminate Configuration Mode The allowed range...

Страница 32: ...ature overshoot and undershoot Slow Mode Providing the slowest heat up time but the narrowest fluctuation range of temperature overshoot and undershoot Point Mode Allowing linear heating up to the tar...

Страница 33: ...ng PID Parameter Calibration The PID parameters for temperature control can be automatically tuned to take your specific operating circumstances into consideration Before starting the auto tuning proc...

Страница 34: ...Press the Control Knob again to start the auto tuning Restoring the Default Settings To change the current settings back to the default settings do as follows 1 Press the CONFIG Button and select the...

Страница 35: ...Knob 2 Then press the Control Knob to confirm the termination of the configuration mode The following display will appear You can also terminate the configuration mode using the RUN STOP Button Refer...

Страница 36: ...all parts or accessories Never immerse this unit in water or any other liquid Do not allow any liquid or wet material to get inside the unit when cleaning Do not reconnect this unit to power outlets...

Страница 37: ...ing is made much easier if spills are attended to promptly Relocation If you need to move the instrument to another place 1 Disconnect the power cord from the power outlet 2 Pack the instrument and it...

Страница 38: ...ets or plugs Replace the damaged part with a proper one Internal circuit failure Contact Fisher Scientific for service Repetitive tripping of the circuit breaker Electrical overload Disconnect all the...

Страница 39: ...ontact Fisher Scientific for service No or too slow temperature change during heating Too low setting of the heating level Turn the heater knob clockwise to increase the heating level Too much media R...

Страница 40: ...ansparent Shield PC 11676271 15386607 FS Support Rod 12 support 400mm M10 11676276 15346617 FS Clamp Holder PP body 12mm 11676277 15356617 FS 3 Prong Clamp 60mm grip Assembly of Support Rod Hand screw...

Страница 41: ...7 1 Section 7 Accessories Transparent Shield Heating Bath Assembly When necessary the transparent shield and or the heating bath can be easily assembled as shown below...

Страница 42: ...te activation Delayed activation Safety Hot top warning C F Warning lamp 50 122 Overheat Prevention Top plate Main body PCB Main Body Aluminum Top plate Ceramic coated aluminum Dimension of top plate...

Страница 43: ...or instrument disposal may lead to actions against you and your organization 1 First check with your laboratory or organization to ensure that you are following all the policies and procedures for dis...

Страница 44: ...ions and according to these operation instructions and maintenance this product is warranted for 24 months against defective materials or workmanship The 24 month warranty period begins from the deliv...

Страница 45: ...9 59 fishersci no Denmark 45 70 27 99 20 fishersci dk Portugal 351 21 425 33 50 pt fishersci com Germany 49 0 180 5258221 de fishersci com Spain 34 002 239 303 es fishersci com Ireland 959 0 1 885 585...

Страница 46: ...Find out more at fishersci com 2017 Thermo Fisher Scientific Inc All rights reserved Trademarks used are owned as indicated at fishersci com trademarks...

Отзывы: