background image

ISOTEMP

®

Refrigerators,

Refrigerator-Freezers and Freezers

Operation Manual and Parts List

MODEL NO.

97-920-1

97 938-1

97-950-1

97-915-1

97-960-1

97-935-1

97-952-1

97-926-1

97-925-1

97-928-1

Содержание ISOTEMP 97 938-1

Страница 1: ...ISOTEMP Refrigerators Refrigerator Freezers and Freezers Operation Manual and Parts List MODEL NO 97 920 1 97 938 1 97 950 1 97 915 1 97 960 1 97 935 1 97 952 1 97 926 1 97 925 1 97 928 1...

Страница 2: ...el 97 920 1 12 General Purpose Laboratory Units 13 Model 97 920 1 13 Model 97 915 1 14 Model 97 960 1 15 Model 97 926 1 16 Flammable Materials Storage Units 17 Overview 17 Model 97 925 1 18 Model 97 9...

Страница 3: ...manner by providing up to the minute information on products pricing specifica tions delivery and return procedures They ll arrange to have your order shipped from one of our many Customer Service Cen...

Страница 4: ...e front should be 3 or more back from the edge to avoid accidental tipping of the unit If possible locate your unit out of direct sunlight and away from heat sources such as a radiator stove or heat d...

Страница 5: ...E A TEMPERATURE THAT WILL CAUSE IT TO EMIT TOXIC FUMES DEATH OR SEVERE INJURY MAY RESULT WARNING BEFORE CONNECTING THE FINAL POWER SUPPLY CHECK THE ELECTRICAL CHARAC TERISTICS OF THE UNIT NAMEPLATE TO...

Страница 6: ...lting serious explosion After the unit wires have been pulled through the horizontal conduit the following procedure is required Turn power off at the circuit breaker before proceed ing Place a small...

Страница 7: ...bottom completely blocking this end of the horizontal conduit 7 INSTALLATION Left Hub Right Hub Wiring Figure 2 Horizontal Conduit Cutaway Insert fiber rope material down into horizontal conduit openi...

Страница 8: ...not to trap air bubbles Immediately wipe off any spilled sealing compound Screw conduit domed cover back onto conduit opening NOTE INITIAL SETUP OF SEALING COMPOUND WILL OCCUR IN APPROXIMATELY 30 MIN...

Страница 9: ...er on a shelf in the center of the chamber Initially rotate the temperature control knob to an arbitrary setting Allow approximately 2 hours for the temperature to initially stabi lize Check the tempe...

Страница 10: ...e affected Use the following procedure to defrost manually Rotate the temperature control knob to the OFF setting Disconnect the power cord from its outlet Remove contents of unit If practical wrap co...

Страница 11: ...as frost has accumulated to 1 4 defrost Keep containers covered when possible to reduce moisture buildup Set operating temperature no colder than neces sary for the items being refrigerated Safety Tip...

Страница 12: ...inge and mount it on the other side tightening its bolts Remove the hole plugs of the door handle with a knife Fit the hole plugs of the door handle to the other side Fit the buffer to its place Mount...

Страница 13: ...z Watts Amps Refrig Temp Range C F Net Wt Lbs kg Ship Wt Lbs kg 97 920 1 120 60 160 1 3 2 to 7 36 to 45 100 46 120 55 NOTE Amps listed are at normal run mode starting amps may be higher MODEL 97 920 1...

Страница 14: ...x 18 5 x 20 48 x 47 x 51 cm 120 60 96 0 8 97 915 1 Model Electrical Characteristics Volts Hz Watts Amps Refrig Temp Range C F Net Wt Lbs kg 35 16 Ship Wt Lbs kg 40 18 2 0 to 7 32 to 45 NOTE Amps list...

Страница 15: ...s Volts Hz Watts Amps Refrig Temp Range C F Net Wt Lbs kg Ship Wt Lbs kg 97 960 1 120 60 160 1 3 2 to 7 36 to 45 Freezer Temp Range C F 6 to 1 21 to 33 100 46 120 55 NOTE Amps listed are at normal run...

Страница 16: ...inches cm Total Vol Cu Ft Model Electrical Characteristics Volts Hz Watts Amps Net Wt Lbs kg Ship Wt Lbs kg Freezer Temp Range C F 97 926 1 120 60 132 1 1 20 to 15 4 to 5 75 34 95 43 NOTE Amps listed...

Страница 17: ...materials inside the unit They are NOT designed for use in Class I Groups C and D environments For these locations use a Fisher Explosion Proof Refrigerator However FMS units are not suitable for use...

Страница 18: ...Net Wt Lbs kg Ship Wt Lbs kg Freezer Temp Range C F 97 925 1 120 60 132 1 1 20 to 15 4 to 5 85 39 110 50 NOTE ALLOW FOR 4 INCHES OF ADDITIONAL SPACE AT THE REAR OF FLAMMABLE MATERIAL STORAGE UNITS TO...

Страница 19: ...bs kg Ship Wt Lbs kg 97 938 1 120 60 160 1 3 2 to 7 36 to 45 100 46 120 55 NOTE Amps listed are at normal run mode starting amps may be higher NOTE THIS UNIT IS DESIGNED FOR FREE STAND ING RECESSED OR...

Страница 20: ...p Range C F Net Wt Lbs kg Ship Wt Lbs kg 97 935 1 120 60 160 1 3 2 to 7 36 to 44 Freezer Temp Range C F 6 to 1 21 to 33 100 46 120 55 NOTE Amps listed are at normal run mode starting amps may be highe...

Страница 21: ...ps Refrig Temp Range C F Net Wt Lbs kg Ship Wt Lbs kg 97 952 1 120 60 160 1 3 2 to 7 36 to 44 Freezer Temp Range C F 6 to 1 21 to 33 100 46 120 55 NOTE Amps listed are at normal run mode starting amps...

Страница 22: ...s Amps Net Wt Lbs kg Ship Wt Lbs kg Freezer Temp Range C F 97 928 1 120 60 132 1 1 20 to 15 4 to 5 90 41 120 55 NOTE ALLOW 5 INCHES OF ADDITIONAL REAR SPACE FOR EXPLOSION PROOF UNITS TO ACCOM MODATE T...

Страница 23: ...ics Volts Hz Watts Amps Refrig Temp Range C F Net Wt Lbs kg Ship Wt Lbs kg 97 950 1 120 60 160 1 3 2 to 7 36 to 45 100 46 120 55 NOTE Amps listed are at normal run mode starting amps may be higher NOT...

Страница 24: ...ction 3 wide x 1 1 2 high Installation Instructions NOTE Not recommended for use on cushioned vinyl flooring 1 Move refrigerator freezer away from wall 2 Prepare roller by loosening wing nut on the in...

Страница 25: ...ny cause the displayed temperature to change one digit Only when the displayed temperature is changing within a period of 20 seconds or greater can the change be related to real thermal changes in the...

Страница 26: ...every 30 seconds and the alarm status lamp 6 to flash during the delay period If the alarm condition is still present at the end of the preset 30 minute delay period the audio alarm will turn on with...

Страница 27: ...unit designs permit easy and rapid cleaning and should not take more than a few minutes Remember to wear protective gloves to prevent frost bite especially when removing items from freezer units Do no...

Страница 28: ...gasket will allow cold air to escape This causes unit to work harder than necessary to maintain cold temperatures Re seat or replace gasket if worn If you have temperature set too cold this may cause...

Страница 29: ...nd pricing please call the Fisher Scientific Customer Relations Department at 1 800 438 4851 and have the unit s model serial and code numbers available This information is located on data plates on t...

Страница 30: ...ungfallen finden Sie unter www thermo com Conformit WEEE Questo prodotto deve rispondere alla direttiva dell Unione Europea 2002 96EC in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici WEE...

Страница 31: ...aining from the respective manufacturer whatever adjustment is reasonable in the light of the manufacturer s own warranty b The Company shall be released from all obligations under its warranty in the...

Страница 32: ...can be found on the dataplate attached to the equipment If available please provide the date purchased the source of purchase manufacturer or specific agent rep organization and purchase order number...

Страница 33: ...275 Aiken Road Asheville NC 28804 United States 057 155 00 Rev A...

Отзывы: