24

17

The goal of the Ground Balancing procedure is to eliminate the sound as the

searchcoil is being pumped over the ground. In some soils, the sound is not

completely eliminated.
If the ground balance adjustment is incorrect, there will be a difference in the

sound as the searchcoil is either moving toward or away from the ground.  It

sounds like you are either 

pulling the sound out of the ground, 

or

pushing the

sound into the ground. 

If either of these conditions exits, repeat the ground

balancing procedure.

POSITIVE AND NEGATIVE RESPONSE 

The purpose of ground balancing is to adjust the metal detector to ignore ground

minerals.  If the setting is incorrect, ground minerals will give either a positive or a
negative 

response, depending on which direction the adjustment is off.

Positive Response

If the GND BAL setting is too high a number, the response of minerals will be
positive

.  This means that when the searchcoil is lowered to the ground in

PinPoint or All Metal Mode, the sound will get louder as the searchcoil

approaches the ground.  The sound will grow quieter as the searchcoil is raised.

What, if anything, you will hear in Discrimination Mode depends on the

discrimination setting.
When searching in an All Metal Mode, if ground balance is properly set to cancel

the ground, and you sweep over a positive hot rock, the rock will give a “zip”

sound similar to that of a metal object. 

Negative Response

If the GND BAL setting is too low a number, the response of minerals will be
negative.  

When the searchcoil is lowered to the ground in PinPoint or All Metal

Mode, the machine will be silent.  The machine will sound off as the searchcoil is

lifted away from the ground.  What, if anything, you hear in Discrimination Mode

depends on the Discrimination setting.
When searching in All Metal Mode a negative hot rock will produce a “boing”

sound after passing over it, making it difficult to know where it is located.  It will

not have the sound and “feel” of a metal object.

GROUND  BALANCING 

Reading the Display

Most gold prospecting and relic hunting is done by ear. Listen for the louder sounds,

riding on top of the constant background hum. 

As you sweep the searchcoil, notice the Fe

3

O

4

(iron oxide) scale to the left of the

display.

This indicates the amount of ground mineralization.

Most black sand is made of magnetite.

Gold nuggets are often found in concentrated black sand deposits.

For the best depth detection in highly mineralized soils, use the All Metal Mode.

For the most accurate Fe

3

O

4

reading, pump the searchcoil over the ground.

While sweeping the searchcoil, also notice the GND PHASE value in the middle of the

screen.

GND PHASe is the ground phase; this indicates the type of minerals in the soil.

Within an area, the ground phase may change.

After ground balancing, periodically compare GND PHASe to GND BAL. If these two

numbers differ by a great deal, you may want to ground balance the detector again.

When not adjusting the knobs, the GND BAL setting will always appear on the

bottom-right of the display.

GND BAL is the detector’s internal ground balance setting. The detector’s default

ground balance setting is 82.9, which is the best starting point for achieving the

correct setting. 

After you perform the Ground Grab

®

procedure, the GND BAL number will change

to match your soil.

Target Scale

The arc across the top classifies metal objects.

each time a target is detected, three segments will illuminate above the arc.

The segments will remain illuminated for three seconds.

This indication shows the approximate classification of the buried metal object.

See the section on Target Display for a more detailed explanation.

Iron is on the left. U.S. dimes and quarters are to the far right.

In an air test, gold indicates right of center -- the larger the gold piece, the

farther to the right. 

In the ground, the ID of gold may jump around with each pass of the searchcoil.

If searching in All Metal Mode, you may want to switch back into Discrimination Mode, after

finding a target, to see a more accurate Target Identification, viewing the 2-digit Target-ID.

OPERATING  IN  ALL  METAL  M ODE

Содержание Gold Bug

Страница 1: ...amouflage with Fisher logo FCCAP Fisher Coffee Mug 16oz stainless steel and plastic FMUG Fisher T Shirt 100 cotton with Fisher Logo Sizes S M LG XL XXL FTSHIRT Replacement Accessory Searchcoils 11 DD...

Страница 2: ...2 39...

Страница 3: ...ontrols 13 Control Panel 13 Control Knobs Off On Gain 14 Disc All Metal Threshold 15 Touchpad Controls Ground Grab Computerized Ground Balancing Pinpoint 15 and 15 Operating in All Metal Mode Ground G...

Страница 4: ...d passe pas l intensit n cessaire l tablissement d une communication satisfaisante Introduction to the Gold Bug The new Gold Bug is unique among gold prospecting metal detectors for its combination o...

Страница 5: ...MINATION When the detector emits different tones for different types of metals and when the detector eliminates certain metals we refer to this as the detector discriminating among different types of...

Страница 6: ...d leave no damage Remove and dispose of any and all trash and litter found Appreciate and protect our inheritance of natural resources wildlife and private property Act as an ambassador for the hobby...

Страница 7: ...le 6 Twist the LOCKING COLLAr fully in the clockwise direction until it locks 7 repeat this process on the LOWer STeM 8 Using the BOLT and KNUrLeD KNOB attach the SeArCHCOIL to the LOWer STeM 9 Adjust...

Страница 8: ...ies Do not use Heavy Duty batteries rechargeable batteries can also be used If you wish to use rechargeable batteries we recommend using a Nickel Metal Hydride rechargeable battery The battery compart...

Страница 9: ...the surface Never swing the searchcoil like a pendulum WrONG COrreCT QUICK START DEMONSTRATION I Supplies Needed a Nail a Zinc Penny dated after 1982 a Nickel a Quarter II Position the Detector a Plac...

Страница 10: ...ore intermittent nature than electrical interference The second most common cause is a loose searchcoil connector The noise from a loose connector will usually be very erratic or intermittent in natur...

Страница 11: ...etal detectors Overall the potential for electromagnetic Interference eMI is greater than it was just a few years ago Modern high end metal detectors are a lot more sensitive than older units this als...

Страница 12: ...to always carry a magnet to help discriminate gold from hot rocks and iron Gold will not be attracted to a magnet Pieces of iron will always be attracted to a magnet Negative hot rocks will almost al...

Страница 13: ...em unless you have the claim owner s permission Prospecting clubs such as the Gold Prospector Association of America GPAA often own claims which are open to its members and sponsor group outings to pr...

Страница 14: ...e the loss of sensitivity resulting from discrimination is enough to cause those little nuggets to vanish If you have gone many hours without finding gold and are wondering if there is something wrong...

Страница 15: ...ion of the object and its distance from the searchcoil As a starting point refer to the table below TARGET Readout The table below lists some common approximate target values With experience in the fi...

Страница 16: ...objects in the ground The searchcoil must be in motion for objects to be detected Ground Grab Computerized Ground Balancing Naturally occurring minerals in soil look like metal to a metal detector so...

Страница 17: ...d and feel of a metal object GROUND BALANCING Reading the Display Most gold prospecting and relic hunting is done by ear Listen for the louder sounds riding on top of the constant background hum As yo...

Страница 18: ...eved by first performing the Ground Grab Computerized Ground Balancing procedure in All Metal Mode The ground balance setting achieved using Ground Grab Computerized Ground Balancing will carry over i...

Страница 19: ...uce a hum volume and pitch of the hum increase with target strength The approximate target depth in inches will be indicated in the center of the screen The depth scale is calibrated to coin sized obj...

Страница 20: ...NOT BE DETECTED Values from 20 to 49 will induce a LOW tone Values from 50 to 100 will induce a HIGH tone OPERATING IN DISCRIMINATION MODE In Discrimination Mode pressing or will change two detection...

Отзывы: