517794B
37
Reassembly:
(a) Fit the Housing Pump o’ring to the Outer Bowl. When replacing or refitting the pump housing,
a new o’ring must be fitted.
(b) Refit the Pump Housing.
Note: This should be done with the Pump Cap & Hood in place, but it is not essential.
(c) Press the pump to its home position as much as possible by hand, then use the bolts to evenly
torque the pump down.
(d) Tighten the pump bolts to a torque of 2Nm.
Note: If the bolts happen to strip when refitting the pump housing, refer to the Pump
Housing – Stripped Pump Housing Procedure (refer to Section 18.1).
17.14 Removal of Recirculation Hose
(a) If the bowl is full of water drain or bail as
much of the water as possible from the
machine prior to continuing. To assist with
bailing the water, the inner bowl can be
removed.
(b) Follow procedures for removal of neck ring
(c) Lift the recirculation hose upwards and out
of its position on the outer bowl.
(d) Lay machine down or against a wall. If
leaning the machine against a wall ensure
that the machine is stable, and take
necessary precautions not to damage the
wall or the machine.
(e) Depress the two ends of the clip and slide
the clip away from the pump housing.
(f) The hose can now be removed.
Reassembly:
Refit in the reverse manner, ensuring the recirc
hose clip faces away from the cabinet.
Clip must face away from cabinet
Содержание WL26CW1
Страница 1: ...517794B PHASE 7 AQUASMART HI EFFICIENCY WASHER Service Supplement Supplementary Manual to 517792A...
Страница 2: ...517794B 2...
Страница 30: ...517794B 30 16 WIRING DIAGRAM...
Страница 40: ...517794B 40...
Страница 41: ...517794B 41 19 NOTES...