VENTING CLEARANCES
This cooktop requires adequate supply of cool air to fully function. The base of the cooktop
must have direct unrestricted ventilation to the room where the cooktop is installed. There
must be a 4mm air gap at the front of the cooktop.
DRAWER OR OTHER OBSTRUCTION
OVEN WITH COOLING FAN
Drawer or other obstruction
A
B
D
C
Oven* with cooling fan
A
C
B
CLEARANCE DIMENSIONS
IN
MM
A
Minimum ventiliation gap at the front of the cooktop
3/16
4
B
Minimum clearance from bottom of chassis to drawer or
other obstruction
2 9/16
65
C
Minimum ventiliation gap at the rear of the cooktop
13/16
20
D
Minimum diameter of cooling air hole
2
50
CLEARANCE DIMENSIONS
IN
MM
A
Minimum ventiliation gap at the front of the cooktop
3 /16
4
B
Minimum ventiliation gap at the rear of the cooktop
13/16
20
C
Minimum diameter of cooling air hole
2
50
*Some ovens require installation in a sealed box. Please refer you oven installation guide for
more information.
10