background image

SAFETY AND WARNINGS

!

 WARNING!

Electric Shock Hazard

Failure to follow this advice may result in 

electric shock or death.

•  Disconnect the appliance from the mains 

electricity supply before carrying out any work 

or maintenance.

•  Connection to a good earth wiring system is 

essential and mandatory.

•  Alterations to the domestic wiring system must 

only be made by a qualified electrician.

!

 WARNING!

Cut Hazard

Failure to use caution could result in injury.

•  Take care: some edges are sharp.

READ AND SAVE THIS GUIDE

General Use

 

z

Read these instructions carefully before installing this product.

 

z

Save these instructions for the local electrical inspector’s use.

 

z

Installation must comply with your local building and local electricity regulations.

 

z

Electrical installation (including electrical grounding) must be done in accordance with 

the National Electrical Code, ANSI/NFPA70 – latest edition and/or local codes. In Canada: 

Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical 

Codes Part 1 and/or local codes. Particular attention shall be given to the relevant 

requirements regarding ventilation.

 

z

This appliance is to be installed and serviced only by Fisher & Paykel trained and supported 

service technician or qualified person.

 

z

The manufacturer accepts no responsibility for the incorrect installation of appliances. 

Incorrect installation may result in personal injury, damage to property and may invalidate 

any warranty or liability claims.

 

z

Do not modify this appliance.

 

z

Do not use or store flammable materials on or near this appliance.

 

z

Packing elements (eg plastic bags, polystyrene foam, staples, packing straps etc) and tools 

should not be left around during and after installation, especially if they are within easy 

reach of children, as these may cause serious injuries.

 

z

Make sure you recycle the packaging material.

 

z

Before disposing of any appliance, make sure that it can no longer be used and that all 

hazardous parts are removed or made harmless, so that children playing with the old 

appliance cannot harm themselves.

 

z

Only genuine replacement parts may be used for servicing the appliance. These are 

available from your nearest Fisher & Paykel Service Center.

 

z

This cooktop must be connected to the mains power supply only by a suitably 

qualified person.

 

z

DO NOT use adapters, reducers, or branching devices when connecting the cooktop to the 

mains power supply to prevent overheating and fire.

 

z

The power supply cable must not touch any hot parts and must be positioned so that its  

temperature will not exceed 165°F (75°C) at any point.

 

z

This cooktop requires adequate supply of cool air to fully function. The base of the 

cooktop must have direct unrestricted ventilation to the room where the cooktop is 

installed. There must be a 3/16" (4mm) air gap at the front of the cooktop (see ‘Venting 

Clearances’ page).

2

Содержание PROFESSIONAL 9 Series

Страница 1: ...BLACK INDUCTION COOKTOP CI304PTX CI365PTX models INSTALLATION GUIDE US CA...

Страница 2: ...llation of appliances Incorrect installation may result in personal injury damage to property and may invalidate any warranty or liability claims z Do not modify this appliance z Do not use or store f...

Страница 3: ...alling a rangehood that projects horizontally a minimum of 5 127mm beyond the bottom of the overhead cabinets During installation please ensure the following y Seal the exposed bare edges of the cutou...

Страница 4: ...Clamping brackets 4 and screws 4 Wrench Hex key Foam tape 1 Crosshead screwdriver Router Silicone Cutter COMPONENTS REQUIRED PARTS SUPPLIED TOOLS REQUIRED 4...

Страница 5: ...A Overall height of cooktop 3 13 16 97 B Overall width of cooktop 30 762 C Overall depth of cooktop 21 533 D Height of chassis 2 1 16 53 E Width of chassis 28 3 8 720 F Depth of chassis 19 482 G Heigh...

Страница 6: ...Overall height of cooktop 3 3 8 86 B Overall width of cooktop 35 3 8 899 C Overall depth of cooktop 20 7 8 530 D Height of chassis 2 50 E Width of chassis 33 3 4 858 F Depth of chassis 19 1 16 484 G...

Страница 7: ...C Corner radius of cutout max 3 8 max 10 D Offset overhang allowance 1 9 16 39 30 MODEL CUTOUT DIMENSIONS CI365PTX IN MM A Overall width of cutout 34 1 4 870 B Overall depth of cutout 19 7 16 494 C Co...

Страница 8: ...F Minimum clearance from countertop to overhead cabinet not directly above the cooktop 23 1 2 450 G Maximum depth of overhead cabinetry 13 330 H Minimum distance between overhead cabinets either side...

Страница 9: ...ion box 9 230 F Minimum clearance from countertop to overhead cabinet not directly above the cooktop 23 1 2 450 G Maximum depth of overhead cabinetry 13 330 H Minimum distance between overhead cabinet...

Страница 10: ...IMENSIONS IN MM A Minimum ventiliation gap at the front of the cooktop 3 16 4 B Minimum clearance from bottom of chassis to drawer or other obstruction 2 9 16 65 C Minimum ventiliation gap at the rear...

Страница 11: ...harp cutter or trimmer knife Take care not to damage the benchtop 4 Gently lower the cooktop into the cutout ensuring you have access below the countertop to fit and secure the brackets 5 Locate the s...

Страница 12: ...nduit connector Junction box 3 wire cable from power supply White wire Black wires Red wire Green Yellow wire CSA or UL listed conduit connector Junction box 4 wire cable from power supply White wire...

Страница 13: ...Complete and keep for safe reference Model Serial No Purchase Date Purchaser Dealer Address Installer s Name Installer s Signature Installation Company Installation Date Check that all the cooking zo...