16
Installation instructions
Ventilation requirements (GB & IE only)
The appliance should be installed into a room or space with an air supply in accordance with BS
5440-2:2000.
For rooms with a volume of less than 5 m
3
- permanent ventilation of 100 mm
2
free area will be
required.
For rooms with a volume of between 5 m
3
and 10 m
3
a permanent ventilation of 50 cm
2
free area
will be required unless the room has a door which opens directly to the outside air in which case
no permanent ventilation is required.
For rooms with a volume greater than 10 m
3
- no permanent ventilation is required.
Important!
Regardless of room size, all rooms containing the appliance must have direct access to the outside air via
an openable window or equivalent.
Where there are other fuel burning appliances in the same room, BS 5440-2:2000 should be
consulted to determine the correct amount of free area ventilation requirements.
Gas installation (GB & IE only)
Important!
This cooker uses NATURAL GAS only and cannot be used on any other gas without modification. This
appliance is manufactured for conversion to LPG if required. If the injectors are not supplied they can be
obtained from the After-Sales Service.
Installation and service regulations
Important!
This appliance must be installed and serviced only by a suitably qualified and registered person, and in
accordance with the current editions of the following standards and regulations or other locally applicable
regulations:
Gas Safety (Installation and Use) Regulations
Building Regulations
British Standards
Regulations for Electrical Installation
Failure to install the appliance correctly could invalidate any manufacturer’s warranty
and lead to prosecution under the above-quoted regulation.
Gas connection
The installation of the cooker to Natural Gas or LP Gas must be carried out by a qualified
gas engineer. Installers shall take due account of the provisions of the relevant British
Standards Code of Practice, the Gas Safety Regulations and the Building Standards (Scotland)
(Consolidation) Regulations issued by the Scottish Development Department.
Note: It is recommended that the gas connection to the cooker is installed with a flexible
connecting tube made to BS 5386.